Search Tips
- Words separated by spaces will be searched for individually: enter wall bracing and the website will search for wall OR bracing
- Use double quotes around multi-word terms to search for an exact term: "wall bracing"
- Use AND, OR and NOT to search for multiple words or exclude words: wall AND bracing, or wall NOT bracing
APA Search Results
This search function provides links to stories and documents within the APA website and Publications Library. If the search results were inconclusive, try simplifying your search: i.e. 'plywood' instead of '3/4" plywood'. View more search tips.
Search for member manufacturers and their products.
APA Web Search Results
More About Dimensional Stability and Flatness :: Performance Panels :: APA - The Engineered Wood Association
... manufacturers. More about us. More About Dimensional Stability and Flatness The shrinking of solid wood along the grain ... of APA testing, consult APA Technical Topic Dimensional Stability, Form TT-028. Print Page E-mail Page Sign up for ... (more)
Dimensional Stability and Flatness :: Performance Panels :: APA - The Engineered Wood Association
... wood products manufacturers. More about us. Dimensional Stability and Flatness It is a well-known fact that when wood ... stability than other wood-based building products. Keep reading about the dimensional stability and flatness of wood ... (more)
Railroad Construction | APA - The Engineered Wood Association
... Glued laminated timber (glulam) has the dimensional stability, strength, and fastener values that make it an ideal ... deck panels. The Glulam Advantage for Railroads Dimensional Stability – Glulam is manufactured from kiln-dried lumber ... (more)
A Glossary of Engineered Wood Terms | APA - The Engineered Wood Association
... plywood its excellent strength, stiffness and dimensional stability. In addition to a variety of sheathing, siding ... and oriented for maximum strength, stiffness and stability. The individual strands are typically three to four inches ... (more)
Success of OSB Built on Foundation of Continuous Process Improvement | APA - The Engineered Wood Association
... resistance, reduce flame spread, and improve dimensional stability. Edge sealing: Improved edge sealers reduce thickness ... (more)
APA Quality Services | APA - The Engineered Wood Association
... attributes as bending strength and stiffness, dimensional stability, bond durability, impact resistance, etc. Test ... (more)
Rim Board ® | APA - The Engineered Wood Association
... These engineered wood Rim Boards have greater dimensional stability, higher strength, increased structural reliability ... (more)
Panel Attributes :: Performance Panels :: APA - The Engineered Wood Association
... resist both uniform and point loads. • Dimensional stability and flatness: Panels remain relatively consistent in size ... (more)
Highway & Billboard Sign Manufacturing :: Performance Panels :: APA - The Engineered Wood Association
... today. They are ideal in size, strength, weight, dimensional stability and rack resistance. In addition, panels are easy ... (more)
APA Quality Services | APA - The Engineered Wood Association
... attributes as bending strength and stiffness, dimensional stability, bond durability, impact resistance, etc. Test ... (more)
Publication Search Results
Technical Topics: Moisture-Related Dimensional Stability
Discusses the effect of moisture on linear expansion and thickness swell of wood structural panels. Available only as a downloadable pdf file. Updated December 2006. (Form TT-028 - 5 pages)
Get a Free PDF Download 503 KBTechnical Topics: Allowable Depth-To-Width Ratios for Glulam Beams
Prescriptive lateral-bracing recommendations. Available only as a downloadable pdf file. Updated June 2008. (Form TT-085 - 2 pages)
Get a Free PDF Download 207 KBDimensional Stability of Plywood Composite Panels
Research Report 143. Determination of the effects of core-board composition on hygroscopic expansion of veneer-faced composite panels. Issued November 1980. (Form D455 - 23 pages)
Purchase Paper Copy Now ($2.00) or
Get a Free PDF Download 1.5 MBDimensional Performance of Wood-Based Siding
Research Report 149. Development of methodology for evaluating buckle performance and edge stability for inclusion in the performance standard for APA Rated Siding. Revised March 1997. (Form L310 - 54 pages)
Purchase Paper Copy Now ($5.00) or
Get a Free PDF Download 1.7 MBEWS Technical Note: Dimensional Changes in Structural Glued Laminated Timber
Why acclimatization causes increase and decrease in the dimensions of a glulam member, and how such changes can be predicted and accounted for in the design process. Issued October 1998. (Form EWS Y260 - 6 pages)
Purchase Paper Copy Now ($1.00) or
Get a Free PDF Download 138 KBTechnical Note: Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction
Because moisture vapor can move through exterior wall systems, care must be taken with respect to the design of the wall to prevent excessive condensation and minimize moisture-related problems. This document addresses the water vapor permeance of structural wood panels, vapor retarders and their role in wall-system design. Issued February 2009. Available only as a downloadable PDF. (Form J450 - 6 pages)
Get a Free PDF Download 248 KBPredicting Buckling of Plywood Composite Panels
complete title: Research Report 144, Predicting Buckling Performance of Plywood Composite Panels for Roofs and Floors. Evaluation of buckling in plywood and composite panels via full-scale and laboratory-scale testing to createan empirical stability index based on Euler's formula. Revised May 1997. (Form D460 - 27 pages)
Purchase Paper Copy Now ($3.00) or
Get a Free PDF Download 1.3 MBAPA Full-Scale House Test Project: Progress Report 1
Full Name: APA Full-Scale House Test Project: Progress Report 1, Overview of Test Project. Reports on APA’s three-dimensional, full-scale house test project. This extensive study will investigate the response of braced walls and evaluate how various structural components work as a whole. Available as a PDF only. Issued November 2006. (Form 3D-001 - 4 pages)
Get a Free PDF Download 454 KBAPA Full-Scale House Test Project: Progress Report 2
Full Name: APA Full-Scale House Test Project: Progress Report 2, Effect of Return Corners and Hold Downs. Reports on APA’s three-dimensional, full-scale house test project. Available as a PDF only. Issued January 2007. (Form 3D-002 - 4 pages)
Get a Free PDF Download 159 KBAPA Full-Scale House Test Project: Progress Report 4
Full Name: APA Full-Scale House Test Project: Progress Report 4, 3-D Testing with 6:1 Aspect Ratio Portal Frame Wall Bracing. Reports on APA’s three-dimensional, full-scale house test project. Available as a PDF only.Issued January 2007. (Form 3D-004 - 7 pages)
Get a Free PDF Download 315 KB