Skip to main content

Technical Document Library

Research-Backed Guidance for Every Project

Find Documents By

Results for E30

Filters Reset

Engineered Wood Type

Products

Document Type

Standards
Product Evaluation Reports

Select Product or Manufacturer

or
Technical Guides
Typical Details
Case Studies
Market Analysis Reports

Reason for Use

Design & Specification
Construction & Installation
Learning the Fundamentals
Industrial Applications

Language

Language

Country

Country

Most Relevant

2024 Multi Product shots Engineered Wood Construction Guide Technical Guides - E30 This publication provides a comprehensive overview of engineered wood construction systems for residential, commercial and industrial buildings Open Soffit Typical Details - DT-EWG-31 This detail shows APA Rated sheathing panels installed as an open soffit on exposed roof rafters with weather-protected edges. Preframed Roof Panel 8' x 8' Perpendicular to Supports Typical Details - DT-EWG-32 This detail shows a prefabricated APA wood structural panel roof assembly with purlins installed perpendicular to the supports. Shear Wall Hold-Down Anchor Typical Details - DT-EWG-33 This detail shows a hold down anchor assembly connecting a shear wall to a concrete foundation to resist overturning forces. APA Glued Floor System Typical Details - DT-EWG-1 This detail shows an APA glued floor system using APA Rated Sturd-I-Floor or sheathing panels. APA Panel Roof Sheathing Typical Details - DT-EWG-2 This detail shows APA Rated sheathing panels installed as roof decking over rafters or trusses with panel clips, asphalt or wood shingles, and proper edge and joint spacing. APA Panel Stair Treads and Risers Typical Details - DT-EWG-3 This detail shows APA panel stair treads and risers installed on stringers in two configurations, using plywood, OSB, or composite panels with 8d common nail fastening. APA Panel Subflooring Typical Details - DT-EWG-4 APA Rated sheathing panels installed as subflooring over 2x joists, I-joists, or floor trusses with tongue-and-groove or blocked edges on a wood-framed floor system. APA Panel Wall Sheathing Typical Details - DT-EWG-5 This detail shows APA Rated wall sheathing applied in two orientations- strength axis across or parallel to studs- with weather-resistive barrier and siding on a wood-framed wall. APA Rated Lap Siding Over Wood Structural Panel Sheathing Typical Details - DT-EWG-6 This detail shows APA Rated lap siding installed over wood structural panel sheathing with a weather-resistive barrier on a wood-framed exterior wall assembly. APA Rated Panel Siding Over Wood Structural Panel Sheathing Typical Details - DT-EWG-7 This detail shows APA Rated siding panels applied over wood structural panel sheathing with a weather-resistive barrier on a wood-framed wall assembly. APA Rated Sturd-I-Floor 16, 20, and 24 o.c. Typical Details - DT-EWG-8 This detail shows APA Rated Sturd-I-Floor panel installation at 16", 20", or 24" o.c. joist spacing with tongue-and-groove edges over a floor framing system. APA Rated Sturd-I-Floor 32 and 48 o.c. Typical Details - DT-EWG-9 This detail shows APA Rated Sturd-I-Floor panel installation at 32" or 48" o.c. joist spacing with tongue-and-groove joints over a crawl space floor framing system. APA Rated Sturd-I-Floor 48 o.c. Typical Details - DT-EWG-10 This detail shows APA Rated Sturd-I-Floor 48 o.c. panels installed over a post-and-beam floor framing system with 4x4 posts, 4x girders, and tongue-and-groove panel edges. APA Sturd-I-Wall (Horizontal Panel Siding Installation) Typical Details - DT-EWG-12 This detail shows APA Rated horizontal panel siding applied directly to wall framing in an APA Sturd-I-Wall system. APA Sturd-I-Wall (Vertical Panel Installation) Typical Details - DT-EWG-13 This detail shows APA Rated vertical panel siding applied directly to wall framing in an APA Sturd-I-Wall system with weather-resistive barrier. Brick Veneer Over APA Panel Sheathing Typical Details - DT-EWG-14 This detail shows brick veneer or masonry cladding installed over APA Rated wood structural panel sheathing. Closed Soffit Typical Details - DT-EWG-15 This detail shows a closed soffit assembly using APA rated roof sheathing and exterior panels for the closed soffit with continuous screened or louvered venting. Energy-Conserving Wall Assemblies Typical Details - DT-EWG-16 This detail shows two energy-conserving exterior wall assemblies. FM Class 1-105 Typical Details - DT-EWG-17 This detail shows an FM Class 1-105 rated flat roof assembly using wood structural panels over open-web trusses. FM Class 1-120 Typical Details - DT-EWG-18 This detail shows an FM Class 1-120 rated flat roof assembly using wood structural panels over steel joists. FM Class 1-135 Typical Details - DT-EWG-19 This detail shows an FM Class 1-135 rated flat roof assembly using wood structural panels. FM Class 1-90 Typical Details - DT-EWG-20 This detail shows an FM Class 1-90 rated flat roof assembly using wood structural panels with foam insulation, fiberboard cover board, and built-up or modified bitumen roofing. Heavy Timber Construction Typical Details - DT-EWG-21 This detail shows a heavy timber roof construction assembly using APA Rated Sturd-I-Floor T&G panels over structural glulam or solid timber beams with built-up roofing. Horizontal Beltline Joints Typical Details - DT-EWG-22 This detail shows three horizontal beltline joint configurations for APA panel siding at floor lines in multistory construction. Horizontal Wall Joints Typical Details - DT-EWG-23 This detail shows three horizontal joint configurations for APA panel siding — butt and flash, lap, and shiplap — each with blocking flatwise or edgewise at the joint location. Installation of APA Plywood Underlayment Typical Details - DT-EWG-24 This detail shows APA plywood underlayment installation over APA Rated sheathing subfloor. Noise-Resistant Floor Assembly Typical Details - DT-EWG-26 This detail shows noise-resistant floor/ceiling assembly using APA Rated sheathing subfloor, lightweight concrete topping, resilient channels, and gypsum wallboard. Noise-Resistant Party Wall Typical Details - DT-EWG-27 This detail shows a noise-resistant wall assembly in plan view using staggered 2x4 studs on 2x6 plates with APA Rated sheathing and gypsum wallboard to reduce sound transmission. One-Hour Combustible Floor-Ceiling And Roof-Ceiling Assemblies - I-Joists Typical Details - DT-EWG-28 This detail shows one-hour fire-resistive floor/ceiling assemblies using wood I-joists with APA Sturd-I-Floor decking and gypsum wallboard ceiling systems with furring channels. One-Hour Combustible Floor-Ceiling Assemblies - Lumber Joists Typical Details - DT-EWG-29 This detail shows two one-hour fire-rated floor/ceiling assemblies with lumber joists. One-Hour Fire-Rated Exterior Load-Bearing Wall Assembly Typical Details - DT-EWG-30 One-hour fire-rated exterior wall assembly using APA Rated siding, gypsum sheathing, weather-resistive barrier, and Type X gypsum wallboard over 2x4 wood stud framing. Stucco Over APA Panel Sheathing Typical Details - DT-EWG-34 Stucco cladding assembly applied over APA Rated wood structural panel sheathing with two layers of weather-resistive barrier, self-furring metal lath, and metal bead. Typical Connections to Engineered Flat Roof Members Typical Details - DT-EWG-35 This detail shows four connection methods for flat roof systems: to wood I-joists, open-web parallel-chord wood trusses, steel bar joists with wood nailer and glulam beams. Typical Panel-To-Metal Framing Systems Typical Details - DT-EWG-36 This detail shows 4 methods for attaching APA panel deck to metal framing systems including nailable steel joists, nailer-anchored, and direct-to-formed steel joist configurations. Vertical Inside and Outside Corner Joints Typical Details - DT-EWG-37 This detail shows vertical corner joint configurations for APA panel and lap siding — butt and caulk, corner board lap joints, and lap siding corners — in horizontal section view. Vertical Wall Joints Typical Details - DT-EWG-38 This detail shows four vertical joint configurations for APA panel siding butt, shiplap, reverse board and batten, T1-11 and channel groove, and vertical batten.