Skip to main content

Technical Document Library

Research-Backed Guidance for Every Project

Find Documents By

Results for PS 1

Filters Reset

Engineered Wood Type

Products

Document Type

Standards
Product Evaluation Reports

Select Product or Manufacturer

or
Technical Guides
Typical Details
Case Studies
Market Analysis Reports

Reason for Use

Design & Specification
Construction & Installation
Learning the Fundamentals
Industrial Applications

Language

Language

Country

Country

Most Relevant

APA-Generic-Content-Card-Technical-Topic Recommended Uniform Live Loads for PS 1 APA 303 Siding Technical Topic - TT-021 Table of recommended uniform live loads for PS 1 APA 303 siding when used as open soffit or combined roof decking-ceiling with long dimension perpendicular to supports. I-Joist Fire Assembly with Gypsum Board at Bottom Flange Typical Details - DT-FPF-1 This detail shows 1/2" gypsum board or 5/8" wood structural panel installed at the bottom flange of an I-joist floor assembly for fire protection per IRC Section R702.3. Voluntary Product Standard PS 1-22, Structural Plywood Standards - L870 This publication is the national standard for performance requirements and marking plywood for construction and industrial uses. Concrete Masonry Crawl Space Foundation Typical Details - DT-BB-1 This detail shows concrete masonry crawl space foundation. 19/32" T&G APA Plywood Underlayment, 15/32" APA Wood Structural Panel Subfloor, 3-Dimensional Detail Typical Details - DT-FR-1 This detail shows floor assembly of APA wood structural panel subfloor over plywood underlayment, building paper, and joists with gypsum wallboard ceiling below. Alternate Insulated Three-Stud Corner (with Drywall Clips) Typical Details - DT-AF-1 This detail shows an alternative insulated 3-stud corner framing assembly with drywall clips to support the gypsum from one stud. Angle Bracket Hanger Typical Details - DT-SPR-1 This detail shows angle bracket hanger assembly for supporting steel sprinkler pipe from wood structural members using blocking and optional fastening methods. APA Glued Floor System Typical Details - DT-EWG-1 This detail shows an APA glued floor system using APA Rated Sturd-I-Floor or sheathing panels. Backer Block Typical Details - DT-IJ-1 This detail outlines backer block installation for single and double I-joist headers. Beam at End Wall Bearing, Nailed Typical Details - DT-GB-1 This detail shows glulam beam bearing at an end wall. The beam is supported by trimmer studs and secured to the king stud with 16d nails. Beveled SIP Wall Typical Details - DT-SIP-1 This detail shows a SIP wall beveled to support a sloped SIP roof that are connected together with panel screws and nails. It also shows sealant, roofing material and cladding. Energy-Heel Truss Attachment to Sheathing Typical Details - DT-RH-1 This detail shows raised heel energy truss attachment to an exterior wall for additional attic insulation space. Force Transfer Around Openings Shear Walls Typical Details - DT-FTO-1 This detail shows the layout of a force transfer around opening shear wall. Garage Door Header to End Wall, King Stud Nailed to Beam Typical Details - DT-GH-1 This detail shows a connection of a garage door header at and end wall where a glulam beam is connected to a king stud with nails. Nailer Anchored with Power Driven Fasteners Typical Details - DT-WOM-1 This detail shows wood nailer attachment to steel wide flange beam using drive pins to support APA panel deck, secured with power driven fasteners. R20 Wall—2x4 Framing Typical Details - DT-CWA-1 This detail shows R20 2x4 wall assembly at 16" o.c. with insulated header, insulated siding (R3 min.), insulated corner, R15 cavity insulation, and wood structural panel sheathing. UL Class 90 (NM519) Typical Details - DT-WWR-1 This detail shows a UL Class 90 rated roof assembly using two-ply asphalt glass fiber mat over plywood deck with Douglas-fir or Southern pine framing. Wind Rated Roofs: UL Class 90 (NMS519) Typical Details - DT-WRR-1 This detail shows UL Class 90 rated roof assembly with two-ply asphalt glass fiber mat hot-mopped over plywood sheathing on wood framing with rayon tape. FM Class 1-135 Typical Details - DT-EWG-19 This detail shows an FM Class 1-135 rated flat roof assembly using wood structural panels. FM Class 1-105 Typical Details - DT-EWG-17 This detail shows an FM Class 1-105 rated flat roof assembly using wood structural panels over open-web trusses. FM Class 1-120 Typical Details - DT-EWG-18 This detail shows an FM Class 1-120 rated flat roof assembly using wood structural panels over steel joists. FM Class 1-90 Typical Details - DT-EWG-20 This detail shows an FM Class 1-90 rated flat roof assembly using wood structural panels with foam insulation, fiberboard cover board, and built-up or modified bitumen roofing. CREDIT REQUIRED FOR IMAGES: 
Credit: © Structurlam ANSI A190.1-2022 Product Standard for Structural Glued Laminated Timber Standards - ANSI A190.1-2022 This ANSI Standard contains requirements for the manufacture and quality control of structural glued laminated timber. ANSI/APA PRS 610.1: Standard for Performance-Rated Structural Insulated Panels in Wall Applications Standards - ANSI/APA PRS 610.1-2023 This standard covers the manufacturing, qualification, quality assurance, design and installation requirements for performance-rated structural insulated panels used in walls Voluntary Product Standard PS 2-18, Performance Standard for Wood Structural Panels Standards - S350 Performance requirements, adhesive bond performance, panel construction and workmanship, dimensions and tolerances, marking and moisture content of wood structural panels. Sway Brace Blocking for Seismic Loads Perpendicular to the Joist 1 Typical Details - DT-SPR-16 This detail illustrates a seismic sway brace blocking configuration, showing the installation of perpendicular diagonal bracing for I-joist floor systems. Minimum 1/2" APA Rated Siding Exterior Plywood, 1" Rigid Foam Insulation Sheathing; Exterior Finish-Elastomeric Coating, 1" Rigid Foam Insulation Sheathing, Minimum 1/2" APA Rated Sheathing Exposure 1 Plywood Typical Details - DT-FR-7 Fire-rated wall assembly of two UL-rated configurations (U330 and U335) with different exterior finishes over wood framing with mineral wool or glass fiber insulation. Single-Layer Floor Systems with I-Joists or Trusses: Minimum 23/32" Tongue & Groove APA Sturd-I-Floor, Two Layers 1/2" Type X Gypsum Wallboard Taped, 3-Dimensional Detail Typical Details - DT-FR-21 This detail shows single-layer wood I-joist floor system with 23/32" T&G APA rated sheathing and two layers of 1/2" gypsum wallboard ceiling providing a fire-rated assembly. LeMay Car Museum in Tacoma, Washington Plywood Design Specification, Supplement 1-23: Design and Fabrication of Plywood Curved Panels Technical Guides - S811 This publication presents the recommended method for the design and fabrication of curved plywood roof panels. It is a supplement to the APA plywood design specification. Stucco (Over Self-Furring Metal Lath), APA Rated Sheathing Exposure 1 Plywood or OSB Typical Details - DT-FR-22 This detail shows a fire-rated wall assembly of stucco over self-furring metal lath with APA rated sheathing, optional insulation, gypsum wallboard, and wood studs. APA Rated Siding Exterior or Other Exterior Finish (Code-Recognized Type), 5/8" Type X Gypsum Sheathing, Minimum 15/32" APA Rated Sheathing Exposure 1 OSB or Plywood Typical Details - DT-FR-2 This detail shows a fire-rated wall assembly using wood structural panel sheathing over studs with gypsum wallboard, fire protective membrane, and glass fiber insulation. APA Rated Siding Exterior or Other Exterior Finish (Code-Recognized Type), 5/8" Type X Gypsum Sheathing, Minimum 7/16" APA Rated Sheathing Exposure 1 OSB or Plywood Typical Details - DT-FR-3 This detail shows fire-rated exterior wall assembly with APA rated siding over sheathing, insulation, 2x4 wood framing at 16" on center and Type X gypsum wallboard interior finish. Single-Layer Floor Systems with I-Joists or Trusses: Minimum 23/32" T&G APA Sturd-I-Floor, 0.019" Galvanized Steel Resilient Channels Maximum 16" o.c., Two Layers 1/2" Type X Gypsum Wallboard Taped, 3-Dimensional Detail Typical Details - DT-FR-20 Single-layer tongue and groove APA-rated sheathing over wood I-joists with resilient channels and two layers of gypsum wallboard ceiling assembly for residential construction. Load-Span Tables for APA Wood Structural Panels Technical Note - Q225 This publication contains uniform load tables for APA trademarked wood structural panels that are manufactured and qualified in accordance with PS 1, PS 2 and APA PRP-108 APA-Generic-Content-Card-Product-Advisory Imported Plywood Panels from Brazil Product Advisory - SP-1185 This publication provides test results for imported plywood panels from Brazil, evaluated for conformance to U.S. Product Standard PS 1 2024 Multi Products shots plywood, OSB, HDO/MDO The Importance of Code-Compliant Concrete Formwork Technical Guides - A236 This publication describes the importance of adhering to PS 1 plywood specifications to meet the material performance criteria outlined in ACI 318 & ACI 347, as mandated by the IBC Atlantic Station Multi-Family Building in Atlanta, Georgia (J130) Plywood Design Specification Technical Guides - Y510 This publication includes section properties, recommended design stresses and design methods for plywood manufactured under Voluntary Product Standard PS 1 La Importancia de Cumplir con la Normativa del Encofrado de Concreto Technical Guides - A236 LA las especificaciones de la norma PS 1 para madera contrachapada para cumplir con los criterios de rendimiento de los materiales establecidos en ACI 318/347, según lo exige el IBC Panel Thickness Tolerances and Labeling Technical Topic - TT-054 This publication provides guidance on how to comply with NIST panel thickness regulations while still providing for traditional specifications used in the U.S. model building codes Atlantic Station Multi-Family Building in Atlanta, Georgia (J130) Panel Design Specification Technical Guides - D510 This publication describes recommended design capacities (ASD) and design methods for wood structural panels manufactured under PS 1 and PS 2 and APA Performance Standard PRP-108. Sized for Spacing Technical Topic - TT-055 This publication discusses the SIZED FOR SPACING notation in the APA trademark stamp and the option of trimming panels slightly to encourage proper panel spacing Heavily Loaded Drywall Carts Technical Topic - TT-024 This publication discusses how to avoid floor panel puncture from drywall carts by consulting PS 2 for minimum concentrated static loads and heavy concentrated loads Engineered Wood Construction Guide: Panel Selection and Specification Excerpt - E30X-PSS This publication is an excerpt from the APA Engineered Wood Construction Guide, providing product descriptions and specification recommendations for wood structural panels Canadian Plywood Grading Guide Technical Guides - Q701 This publication is designed for use by mills as an aid in manufacturing and grading Canadian Standards Association (CSA) plywood panels. Squash Block Typical Details - DT-IJ-15 This detail shows squash blocks at an I-joist with a 1/16" height difference for proper vertical load transfer around the joist. I-Joist Fire Assembly with 0.5 inch Gypsum Board Above Flange Typical Details - DT-FPF-4 This detail shows an I-joist floor assembly with 1/2" gypsum board placed above the bottom flange for fire protection per IRC Section R503. I-Joist Fire Assembly with Gypsum Board Typical Details - DT-FPF-2 This detail shows 1/2" gypsum board fastened to the bottom flange of an I-joist floor assembly for fire protection per IRC Section R702.3.1. I-Joist Fire Assembly with Gypsum Board at Web Holes Typical Details - DT-FPF-3 This detail shows 1/2" gypsum board installed at I-joist web holes for fire protection, shown in two configurations per IRC Section R702.3.1.