Skip to main content

Technical Document Library

Research-Backed Guidance for Every Project

Find Documents By

Results for glulam installation

Filters Reset

Engineered Wood Type

Products

Document Type

Standards
Product Evaluation Reports

Select Product or Manufacturer

or
Technical Guides
Typical Details
Case Studies
Market Analysis Reports

Reason for Use

Design & Specification
Construction & Installation
Learning the Fundamentals
Industrial Applications

Language

Language

Country

Country

Most Relevant

Glulam Product Guide Product Guide - X440 This product guide provides an overview of APA trademarked glulam and discusses design considerations, applications and specification Data File: Selection, Installation and Preparation of Plywood Underlayment Data File - L335 This publication provides recommendations for the installation and preparation of underlayment under finish flooring in residential and light commercial applications Proper Installation of APA Rated Sheathing for Roof Applications Builder Tip - N335 This publication provides step-by-step instructions for roof sheathing installation 4 Best Practices for Glulam Installation Technical Guides - Q705 This publication provides simple steps to proper installation that ensures glulam beams perform as designed. Builder Tips: Keep Glulam Looking Its Best with Proper Storage and Handling Builder Tip - F455 This publication describes best practices for storage and installation of glued laminated timber (glulam). Builder Tips: Proper Storage and Handling of Glulam Beams Builder Tip - R540 This publication provides recommendations for storage and handling of glulam beams. Builder Tips: Proper Selection and Installation of APA Plywood Underlayment Builder Tip - R340 This publication provides an overview of selection, handling, installation and fastening of APA plywood underlayment. 2024 Glulam product shot Engineered Wood Construction Guide: Glulam Selection and Specification Excerpt - E30X-GL This publication is an excerpt from the APA Engineered Wood Construction Guide, providing a description and specification recommendations for glued laminated timber (glulam) Effect of Large Diameter Horizontal Holes on the Bending and Shear Properties of Structural Glued Laminated Timber (Glulam) Technical Note - V700 This publication is a supplement to APA S560, providing an analytical tool in situations when horizontal holes exceeding the prescriptive guidance in APA S560 are necessary Construction on an Apartment using FTAO in Rialto, California Glulam Floor Beams Technical Guides - C415 This publication contains span tables for glulam floor beams in residential construction, tables for substituting glulam for steel beams and design details. Glulam Garage Door Headers Offer Design Options Technical Guides - C410 This publication provides connection details and installation recommendations for glulam in residential garage door framing. Installation of APA Plywood Underlayment Typical Details - DT-EWG-24 This detail shows APA plywood underlayment installation over APA Rated sheathing subfloor. **Please note this image may have been edited or manipulated to enhance visual quality** Glulam Connection Details Construction Guide - T300 This publication shows correct connections and common connection errors involving glued laminated (glulam) timbers Glulam or Multi-Structural Composite Lumber Beams Typical Details - DT-IJ-4 This detail shows I-Joists with top mount hangers supported by a multi-ply structural composite lumber (SCL) beam. This detail is similar for a glulam beam with face mount hangers. Glulam in Residential Building Construction Guide Technical Guides - X450 Describes the selection, specification, design considerations and allowable load tables for APA-trademarked glulam used in residential headers, floor beams and roof beams. fertilizer bins being constructed using Glulam Beams Glulam Appearance Classifications for Construction Applications Technical Note - Y110 This publication clarifies the distinction between appearance considerations and structural properties of glulam timbers and appearance classifications of glulam members. Z-Flashing Installation—APA Rated Siding Typical Details - DT-BB-19 This detail shows z-flashing installation at horizontal joint between APA panel siding. Glulam Beam Camber Technical Note - S550 This publication discusses how camber reduces the adverse effects of beam deflection Sprinkler Pipe Installation Design Details (Supplement to J745) Technical Note - J745_SUP This publication is a supplement to Technical Note: Sprinkler Pipe Installation for APA Performance Rated I-Joists, Form J745, with sprinkler pipe installation design details. ADOBE STANDARD LICENSCING | Standard licenses
Most Adobe Stock photos, vectors, and illustrations come with a Standard license. With a Standard license, you may:
•     Reproduce up to 500,000 copies of the asset in all media, including product packaging, printed marketing materials, digital documents, or software.
•     Include the asset in email marketing, mobile advertising, or a broadcast or digital program if the expected number of viewers is fewer than 500,000.
•     Post the asset to a website or social media site with no limitation on views.
•     Include the asset in some types of products, such as inside a textbook, as long as the primary value of the product is not the asset itself, and the product is not reproduced more than 500,000 times.
•     Share the unmodified asset with your employees and contractors who have contractually agreed to abide by the license terms.
•     Transfer the license to your client or employer.
(With a Standard license, you may not:
•     Distribute the stand-alone file.
•     Create merchandise, templates, or other products for resale or distribution where the primary value of the product is associated with the asset itself. For example, you can't use the asset to create a poster, t-shirt, or coffee mug that someone would buy specifically because of the asset printed on it.
•     Transfer the license to more than one employer or client, unless separately licensed for each.)

Copyright: © Adobe Stock Prevent Callbacks in Wood Flooring Installation Technical Note - T350 This publication discusses how to minimize the risk of future wood flooring problems when moisture at the jobsite is an issue Product-Glued-Laminated-Timber-Glulam Calculating Fire Resistance of Glulam Beams and Columns Technical Note - Y245 This publication describes the natural fire resistance of glulam beams and columns and provides fire endurance calculation methods One-Hour Fire-Rated Glulam Beam (Layup for Simple Span) Typical Details - DT-FR-9 This detail shows cross-section of a one-hour fire-rated glulam beam layup configuration with compression lams at top, core lams in center, and tension lams at bottom. APA-Generic-Content-Card-Technical-Topic Residential Garage Door Installation Details with Prefabricated Wood I-Joists Technical Topic - TT-130 This publication provides a method for garage door installation with back-hangs that are attached to the bottom flange of residential I-joists with lag screws. ADOBE STANDARD LICENSCING | Standard licenses
Most Adobe Stock photos, vectors, and illustrations come with a Standard license. With a Standard license, you may:
•     Reproduce up to 500,000 copies of the asset in all media, including product packaging, printed marketing materials, digital documents, or software.
•     Include the asset in email marketing, mobile advertising, or a broadcast or digital program if the expected number of viewers is fewer than 500,000.
•     Post the asset to a website or social media site with no limitation on views.
•     Include the asset in some types of products, such as inside a textbook, as long as the primary value of the product is not the asset itself, and the product is not reproduced more than 500,000 times.
•     Share the unmodified asset with your employees and contractors who have contractually agreed to abide by the license terms.
•     Transfer the license to your client or employer.
(With a Standard license, you may not:
•     Distribute the stand-alone file.
•     Create merchandise, templates, or other products for resale or distribution where the primary value of the product is associated with the asset itself. For example, you can't use the asset to create a poster, t-shirt, or coffee mug that someone would buy specifically because of the asset printed on it.
•     Transfer the license to more than one employer or client, unless separately licensed for each.)

Copyright: © Adobe Stock Installation of Stucco Exterior Finish Over Wood Structural Panel Wall Sheathing Data File - Q370 This publication describes recommended wall construction methods for the installation of stucco exterior finish over structural wood panel wall sheathing APA Sturd-I-Wall (Vertical Panel Installation) Typical Details - DT-EWG-13 This detail shows APA Rated vertical panel siding applied directly to wall framing in an APA Sturd-I-Wall system with weather-resistive barrier. Exemption of Special Inspection on Glulam Based on the 2019 California Building Code Technical Topic - TT-108 This publication clarifies the intent of the California Building Code exemption for special inspection on glulam outlined in Section 1705.5.4 multiple companies ESR Joint Evaluation Report - ESR-1940 Multiple Companies Canfor, Western Forest Products

Glulam:
Glued-Laminated Timber Combinations and the GAP Computer Program
APA Sturd-I-Wall (Horizontal Panel Siding Installation) Typical Details - DT-EWG-12 This detail shows APA Rated horizontal panel siding applied directly to wall framing in an APA Sturd-I-Wall system. Construction on an Apartment using FTAO in Rialto, California Sprinkler Pipe Installation for APA Performance Rated I-Joists Technical Note - J745 This publication provides guidance on attachment of steel and CPVC sprinkler systems to APA Performance Rated I-Joists. APA-Generic-Content-Card-Technical-Topic Holes in Structural Glued Laminated Timber (Glulam) Rim Board in Light-Frame Wood Construction Technical Topic - TT-135 Provides recommendations for hole size and segment length for glulam rim board for situations where holes are not specified in the construction documents or shop drawings. Colorado Custom Residence in Boulder, Colorado Luxury Boulder Residence Case Studies - R135 This case study discusses how glulam beams reduced costs and streamlined installation on a 5,200 square foot custom Colorado home. Bearing at End Wall, Steel Post Cap Typical Details - DT-GB-8 This detail shows connection of glulam beam bearing on solid-sawn post or glulam column using steel post cap at end wall condition. Beam at End Wall Bearing, Nailed Typical Details - DT-GB-1 This detail shows glulam beam bearing at an end wall. The beam is supported by trimmer studs and secured to the king stud with 16d nails. Beam at End Wall with Floor Joist Over Beam Typical Details - DT-GB-3 This detail shows a glulam beam connection to an end wall with I-joists bearing on the beam. Bearing at End Wall, Steel Tie Plate Typical Details - DT-GB-9 This detail shows a steel tie plate connection for a glulam beam bearing on a wood support at an end condition. Continuous Floor Beam Over Wood Support Typical Details - DT-GB-11 This detail shows two connection options for a continuous glulam floor beam bearing on a wood support. I-Joists Bearing on Floor Beam Typical Details - DT-GB-12 This detail shows I-joists bearing on a glulam floor beam with face nail connections and blocking not shown for clarity. Lumber Joists Bearing on Floor Beams Typical Details - DT-GB-14 This detail shows a cross-section of sawn lumber floor joists secured by toe nails supported by a glulam beam. Beam at End Wall with Floor Joist Flush with Beam Typical Details - DT-GB-2 This detail shows a glulam beam connection to an end wall with flush floor joists or I-joists connected to the beam. Garage Door Header to End Wall, King Stud Nailed to Beam Typical Details - DT-GH-1 This detail shows a connection of a garage door header at and end wall where a glulam beam is connected to a king stud with nails. Beams Butting Over Wood Support Typical Details - DT-GB-6 This detail shows two glulam beams butting over a wood support, with the beams connected to the support using a steel post cap and through-bolts. Continuous Beam Over Intermediate Steel Column Typical Details - DT-GB-10 This detail shows two options for connecting a continuous glulam floor beam to an intermediate steel column using either a steel post cap or steel cap plate. Garage Door Header to End Wall, Steel Tie Plate Typical Details - DT-GH-2 This detail shows a connection of a garage door header and an end wall using a steel plate fastened to a solid wood post, glulam column or studs. Construction on an Apartment using FTAO in Rialto, California Santa Barbara Apartments Case Studies - S125 This case study discusses how glulam beams and wood structural panel shear walls were used to construct a California apartment complex on budget. HarborCenter Hockey Complex Building in Buffalo, New York

CREDIT REQUIRED FOR IMAGES:
Credit: Photograph by Bill Wippert HarborCenter Case Studies - S110 This case study discusses the use of hybrid trusses combining glulam arches, glulam purlins and steel bottom chords at the Buffalo Sabres’ practice ice rinks. LeMay Car Museum in Tacoma, Washington ANSI 117-2025: Standard Specification for Structural Glued Laminated Timber of Softwood Species Standards - ANSI 117-2025 This ANSI Standard provides information for the design of structural glued laminated timber (glulam), reference values for glulam design and specific layup requirements. APA-Generic-Content-Card-Technical-Topic Finishing Glued Laminated Timbers Technical Topic - TT-033 This publication discusses recommendations and exceptions for finishing glulam manufactured entirely from solid-sawn lumber. Heavy Timber Construction Typical Details - DT-EWG-21 This detail shows a heavy timber roof construction assembly using APA Rated Sturd-I-Floor T&G panels over structural glulam or solid timber beams with built-up roofing. Typical Connections to Engineered Flat Roof Members Typical Details - DT-EWG-35 This detail shows four connection methods for flat roof systems: to wood I-joists, open-web parallel-chord wood trusses, steel bar joists with wood nailer and glulam beams. Wood Structural Panel Heavy Timber Roof Construction, 2-Dimensional Detail Typical Details - DT-FR-24 This detail shows a heavy timber roof assembly with wood structural panels, featuring heavy timber or glulam beams supporting tongue-and-groove wood decking with built-up roofing. APA-Generic-Content-Card-Technical-Topic Fire-Retardant-Treated Structural Glued Laminated Timber Technical Topic - TT-127 This publication provides a summary of results of an APA/USDA Forest Product Laboratory pilot test program examining structural properties of Fire-Retardant Treated glulam. Owner's Guide to Understanding Checks in Glued Laminated Timber Technical Guides - F450 This publication addresses common concerns related to checking in glulam and explains how to evaluate if the check effects the glulam’s strength 2024 Multi products OSB and plywood panels APA Performance Rated Panel Subfloors Under Hardwood Flooring Technical Note - R280 This publication provides specification and installation recommendations for panel subfloors to be used under hardwood flooring Appleton Mills Building in Lowell, Massachusetts Appleton Mills Case Studies - R145 This case study discusses how glulam beams, planks, girders and columns were used to structurally and aesthetically restore the historic Appleton Mills complex in Lowell, MA. fertilizer bins being constructed using Glulam Beams Evaluation of Check Size in Glued Laminated Timber Beams Technical Note - R475 This publication discusses checking in glulam beams and includes a flowchart and equations for determining allowable check size APA Case Study: HarborCenter Hockey Complex Building in Buffalo, New York (S110A) Field Notching and Drilling of Glued Laminated Timber Beams Technical Note - S560 This publication provides guidance for notching and drilling on glulam when the end notching and drilling of horizontal though-thickness holes cannot be avoided Apparent and True (shear-free) E Technical Topic - TT-104 This publication explains the difference between apparent modulus of elasticity (MOE) and shear-free MOE in glulam beams Glued Laminated Beam Design Tables Technical Guides - S475 This publication provides recommended design load tables for glulam beam roof and floor applications Water Reservoir in Santa Maria, California Santa Maria Water Reservoir Cover Case Studies - C115 This case study discusses how a glulam roof structure provided decay resistance, seismic performance and cost savings for a municipal water reservoir in California. First United Banks in Texas, Oklahoma 

*MUST CREDIT*
Artist Renderings Courtesy of GENSLER Mass Timber Has Banks Seeing Green Case Studies - V135 This case study discusses how CLT and glulam helped First United Bank achieve construction and energy efficiencies. Product-Glued-Laminated-Timber-Glulam Dimensional Changes in Structural Glued Laminated Timber Technical Note - Y260 Explains how glulam shrinks or swells as moisture content changes, gives shrinkage coefficients by species, and shows how to tell moisture movement from tolerance issues. Washington State University Visitor Center in Pullman, Washington

CREDIT REQUIRED FOR IMAGES:
Credit: Photograph by Benjamin Benschneider Brelsford WSU Visitor Center Case Studies - R130 This case study discusses the Brelsford WSU visitor center’s use of several engineered wood products, including CLT and glulam. Preservative Treatment of Glued Laminated Timber Technical Note - S580 This publication provides a summary of preservatives, treatment recommendations, use, handling and finishing tips for preservative-treated glulam beams APA-Generic-Content-Card-Technical-Topic APA Wood Structural Panels Over Concrete Slabs Technical Topic - TT-007 This publication recommends three methods for the installation of a wood floor system over a concrete slab: sleepers, rigid foam or direct. Backer Block Typical Details - DT-IJ-1 This detail outlines backer block installation for single and double I-joist headers. One North Office Building Development in Portland, Oregon One North Office Buildings Case Studies - S120 This publication discusses how glulam framing and engineered wood helped Portland’s One North development achieve energy efficiency and sustainability. Wall Penetration with Flashing Typical Details - DT-BB-8 This detail shows two-piece flashing installation at wall penetration. Audrain Museum Building in Newport, Rhode Island

*MUST CREDIT*
Photo Courtesy of Ben Jacobson Audrain Museum Case Studies - Q125 This case study explains how glulam beams were used to replace the flooring system of the historic Audrian Building, enabling the building to support multi-ton vintage automobiles. Lone Survivor Foundation Retreat House in Crystal Beach, Texas Lone Survivor House Case Studies - R115 This case study discusses how glulam beams solved complex structural challenges on a pentagon-shaped coastal house. **Please note this image contains an errors or issue with the construction of the building or item. This image should only  be used  for Educational purposes.** Builder Tips: How to Minimize Buckling of Asphalt Shingles Builder Tip - K310 Describes installation techniques for plywood and OSB roof sheathing and roof ventilation techniques that will help minimize the potential for buckling of asphalt shingles Ceiling Flange Hanger Typical Details - DT-SPR-2 This detail shows ceiling flange hanger installation for supporting steel sprinkler system pipes from engineered wood ceiling joists. Sway Brace Blocking for Seismic Loads Perpendicular to the Joist 1 Typical Details - DT-SPR-16 This detail illustrates a seismic sway brace blocking configuration, showing the installation of perpendicular diagonal bracing for I-joist floor systems.