Skip to main content

Technical Document Library

Research-Backed Guidance for Every Project

Find Documents By

Results for Learning the Fundamentals

Filters Reset
Topic

Engineered Wood Type

Products

Document Type

Technical Guides
Typical Details
Case Studies

Language

Language

Country

Country

By Title A-Z

19/32" T&G APA Plywood Underlayment, 15/32" APA Wood Structural Panel Subfloor, 3-Dimensional Detail Typical Details - DT-FR-1 This detail shows floor assembly of APA wood structural panel subfloor over plywood underlayment, building paper, and joists with gypsum wallboard ceiling below. A Guide To Engineered Wood Products Technical Guides - C800 Describes common engineered wood products: plywood, oriented strand board (OSB), I-joist, glued laminated timber (glulam), structural composite lumber (SCL) and rim board. Alternate Insulated Three-Stud Corner (with Drywall Clips) Typical Details - DT-AF-1 This detail shows an alternative insulated 3-stud corner framing assembly with drywall clips to support the gypsum from one stud. Angle Bracket Hanger Typical Details - DT-SPR-1 This detail shows angle bracket hanger assembly for supporting steel sprinkler pipe from wood structural members using blocking and optional fastening methods. **Please note this image may have been edited or manipulated to enhance visually** ANSI/APA PRR 410-2021: Standard for Performance-Rated Engineered Wood Rim Boards Standards - ANSI/APA PRR 410 This standard provides requirements and test methods for qualification and quality assurance for performance rated engineered wood rim board. APA Glued Floor System Typical Details - DT-EWG-1 This detail shows an APA glued floor system using APA Rated Sturd-I-Floor or sheathing panels. APA Panel Roof Sheathing Typical Details - DT-EWG-2 This detail shows APA Rated sheathing panels installed as roof decking over rafters or trusses with panel clips, asphalt or wood shingles, and proper edge and joint spacing. APA Panel Subflooring Typical Details - DT-EWG-4 APA Rated sheathing panels installed as subflooring over 2x joists, I-joists, or floor trusses with tongue-and-groove or blocked edges on a wood-framed floor system. APA Panel Wall Sheathing Typical Details - DT-EWG-5 This detail shows APA Rated wall sheathing applied in two orientations- strength axis across or parallel to studs- with weather-resistive barrier and siding on a wood-framed wall. APA Performance-Rated Rim Boards Technical Guides - W345 This publication details connection requirements and application notes for APA Performance Rated Rim Board APA Rated Lap Siding Over Wood Structural Panel Sheathing Typical Details - DT-EWG-6 This detail shows APA Rated lap siding installed over wood structural panel sheathing with a weather-resistive barrier on a wood-framed exterior wall assembly. APA Rated Panel Siding Over Wood Structural Panel Sheathing Typical Details - DT-EWG-7 This detail shows APA Rated siding panels applied over wood structural panel sheathing with a weather-resistive barrier on a wood-framed wall assembly. APA Rated Siding Exterior or Other Exterior Finish (Code-Recognized Type), 5/8" Type X Gypsum Sheathing, Minimum 15/32" APA Rated Sheathing Exposure 1 OSB or Plywood Typical Details - DT-FR-2 This detail shows a fire-rated wall assembly using wood structural panel sheathing over studs with gypsum wallboard, fire protective membrane, and glass fiber insulation. APA Rated Siding Exterior or Other Exterior Finish (Code-Recognized Type), 5/8" Type X Gypsum Sheathing, Minimum 7/16" APA Rated Sheathing Exposure 1 OSB or Plywood Typical Details - DT-FR-3 This detail shows fire-rated exterior wall assembly with APA rated siding over sheathing, insulation, 2x4 wood framing at 16" on center and Type X gypsum wallboard interior finish. APA Rated Siding Exterior, 5/8" Type X Gypsum Sheathing Typical Details - DT-FR-4 This detail shows a one-hour fire-rated wood-framed wall assembly with Type X gypsum sheathing and wallboard, optional insulation, and APA rated siding exterior finish. APA Rated Sturd-I-Floor 16, 20, and 24 o.c. Typical Details - DT-EWG-8 This detail shows APA Rated Sturd-I-Floor panel installation at 16", 20", or 24" o.c. joist spacing with tongue-and-groove edges over a floor framing system. APA Rated Sturd-I-Floor 32 and 48 o.c. Typical Details - DT-EWG-9 This detail shows APA Rated Sturd-I-Floor panel installation at 32" or 48" o.c. joist spacing with tongue-and-groove joints over a crawl space floor framing system. APA Rated Sturd-I-Floor 48 o.c. Typical Details - DT-EWG-10 This detail shows APA Rated Sturd-I-Floor 48 o.c. panels installed over a post-and-beam floor framing system with 4x4 posts, 4x girders, and tongue-and-groove panel edges. House-Construction-Washington-Illinois APA Simple Solutions: LVL Beams & Headers Technical Guides - S700 This publication discusses the benefits of using laminated veneer lumber (LVL) beams and headers for window and door framing applications APA Sturd-I-Wall (Horizontal Panel Siding Installation) Typical Details - DT-EWG-12 This detail shows APA Rated horizontal panel siding applied directly to wall framing in an APA Sturd-I-Wall system. APA Sturd-I-Wall (Vertical Panel Installation) Typical Details - DT-EWG-13 This detail shows APA Rated vertical panel siding applied directly to wall framing in an APA Sturd-I-Wall system with weather-resistive barrier. APA System Report 102: APA Simplified Wall Bracing Method System Report - SR-102 This report provides an approach to meet the requirements of the 2024, 2021, 2018, 2015 and 2012 IRC simplified wall bracing (Section R602.12). Backer Block Typical Details - DT-IJ-1 This detail outlines backer block installation for single and double I-joist headers. Beveled SIP Wall Typical Details - DT-SIP-1 This detail shows a SIP wall beveled to support a sloped SIP roof that are connected together with panel screws and nails. It also shows sealant, roofing material and cladding. Brick Counter Flashing Details Typical Details - DT-BB-2 This detail shows chimney counter flashing detail of base flashing over shingle underlayment and roof deck, with counter flashing embedded in brick mortar joint. Brick Veneer Over APA Panel Sheathing Typical Details - DT-EWG-14 This detail shows brick veneer or masonry cladding installed over APA Rated wood structural panel sheathing. For images that has been clearly edited (excluding being lightened/darkening, etc.) and trademarks or logos that have been removed or blurred. Build a Better Home: Controlling Mold and Mildew Build A Better Home - A525 This publication outlines the characteristics of mold and mildew, the effect they can have on a structure and its inhabitants, and provides methods for prohibiting their growth. SONY DSC Build A Better Home: Moisture-Resistant Foundation Construction Build A Better Home - A520 This publication details common sources of moisture, preventive measures and design details for multiple foundation types, including slab-on-grade, crawl space and full basement. Build a Better Home: Moisture-Resistant Roof Construction Build A Better Home - A535 This publication describes several roof design and weatherproofing methods used to keep water out of a home’s interior. Build a Better Home: Moisture-Resistant Wall Construction Build A Better Home - A530 This publication describes the primary sources of moisture intrusion in wood wall construction and recommends methods to prevent moisture penetration. Build Energy Efficient Walls Technical Guides - J440 This publication provides five basic steps to construct energy-saving wood wall systems that meet code, are durable to the forces of nature and help homeowners save money. Builder Tips: 4 Ways to Minimize Nail Pops Builder Tip - S300 This publication describes how to reduce nail pops through recommended fastener selection and installation APA Case Study: Raising Up Raised Wood Floors - Murray House in St. Augustine, Florida Builder Tips: Construct a Solid, Squeak-Free Floor System Builder Tip - Q300 This publication describes how to prevent floor complaints and callbacks with proper floor sheathing installation **Please note this image contains an errors or issue with the construction of the building or item. This image should only  be used  for Educational purposes.** Builder Tips: How to Minimize Buckling of Asphalt Shingles Builder Tip - K310 Describes installation techniques for plywood and OSB roof sheathing and roof ventilation techniques that will help minimize the potential for buckling of asphalt shingles Builder Tips: Proper Selection and Installation of APA Plywood Underlayment Builder Tip - R340 This publication provides an overview of selection, handling, installation and fastening of APA plywood underlayment. Canadian Plywood Grading Guide Technical Guides - Q701 This publication is designed for use by mills as an aid in manufacturing and grading Canadian Standards Association (CSA) plywood panels. Cantilever Detail for Vertical Building Offset with Double I-Joist Typical Details - DT-IJ-2 This detail shows cantilevered double I-joists supporting a vertical building offset and specifies connections to the top plate, blocking panels, and Rim Board or APA WSP closure. Closed Soffit Typical Details - DT-EWG-15 This detail shows a closed soffit assembly using APA rated roof sheathing and exterior panels for the closed soffit with continuous screened or louvered venting. Concrete Masonry Crawl Space Foundation Typical Details - DT-BB-1 This detail shows concrete masonry crawl space foundation. Data File: APA Rim Board in Fire Rated Assemblies Data File - D350 This publication provides recommendations for the use of APA rim board in conjunction with fire-rated wall/floor assemblies, based on the US Forest Product Laboratory testing Data File: Selection, Installation and Preparation of Plywood Underlayment Data File - L335 This publication provides recommendations for the installation and preparation of underlayment under finish flooring in residential and light commercial applications Double-Sheathed Shear Walls Technical Topic - TT-115 This technical topic presents the results and discussion of full-scale testing of double-sheathed shear walls with both layers of wood structural panels on a single side. Effect of Overdriven Fasteners On Shear Capacity Technical Topic - TT-012 This publication provides suggested guidelines for determining if overdriven fasteners will affect the shear capacity of diaphragm or shear wall construction Energy-Conserving Wall Assemblies Typical Details - DT-EWG-16 This detail shows two energy-conserving exterior wall assemblies. 2024 Multi Product shots Engineered Wood Construction Guide Technical Guides - E30 This publication provides a comprehensive overview of engineered wood construction systems for residential, commercial and industrial buildings Veneered Laminated Timber Engineered Wood Construction Guide: Cross-Laminated Timber (CLT) Selection and Specification Excerpt - E30X-CLT This publication is an excerpt from the APA Engineered Wood Construction Guide, focusing on selecting and specifying cross-laminated timber for various building applications Engineered Wood Construction Guide: Floor Construction Excerpt - E30X-FC This publication is an excerpt from the APA Engineered Wood Construction Guide, providing information about floor framing and wood structural panel products 2024 Glulam product shot Engineered Wood Construction Guide: Glulam Selection and Specification Excerpt - E30X-GL This publication is an excerpt from the APA Engineered Wood Construction Guide, providing a description and specification recommendations for glued laminated timber (glulam) Engineered Wood Construction Guide: I-Joist Selection and Specification Excerpt - E30X-IJ This publication is an excerpt from the APA Engineered Wood Construction Guide, providing a description and specification recommendations for I-joist House-Construction-Washington-Illinois Engineered Wood Construction Guide: Roof Construction Excerpt - E30X-RC This publication is an excerpt from the APA Engineered Wood Construction Guide, providing a description and application recommendations for engineered wood roof materials Engineered Wood Construction Guide: Wall Construction Excerpt - E30X-WC This publication is an excerpt from the APA Engineered Wood Construction Guide, providing application recommendations for APA wood structural panel wall sheathing. Engineered Wood Handbook & Grade Glossary Technical Guides - X505 This publication provides a list of engineered wood products and common construction terminology explained in easy-to-understand language. Engineered Wood Wall Systems (Canada) Construction Guide - R310 This publication provides an overview of commonly used wall systems and explains how wood structural panels can be used to meet fundamental requirements in wall applications Exterior Deck Water-Resistive System Typical Details - DT-BB-3 This detail shows exterior deck ledger connection to wood I-joist floor system of water-resistant flashing. Construction on an Apartment using FTAO in Rialto, California Floor Squeaks: Causes, Solutions and Prevention Technical Note - C468 This publication discusses typical floor squeak causes and provides corrections and preventative measures. FM Class 1-105 Typical Details - DT-EWG-17 This detail shows an FM Class 1-105 rated flat roof assembly using wood structural panels over open-web trusses. FM Class 1-120 Typical Details - DT-EWG-18 This detail shows an FM Class 1-120 rated flat roof assembly using wood structural panels over steel joists. FM Class 1-135 Typical Details - DT-EWG-19 This detail shows an FM Class 1-135 rated flat roof assembly using wood structural panels. Force Transfer Around Openings Shear Walls Typical Details - DT-FTO-1 This detail shows the layout of a force transfer around opening shear wall. Framing Anchor to Backer Block Typical Details - DT-IJ-3 This detail shows installation of backer and filler blocks for a double I-joist header supporting a stair stringer that is attached with a framing anchor. Glulam or Multi-Structural Composite Lumber Beams Typical Details - DT-IJ-4 This detail shows I-Joists with top mount hangers supported by a multi-ply structural composite lumber (SCL) beam. This detail is similar for a glulam beam with face mount hangers. Hanging Floor for SIPs Typical Details - DT-SIP-3 This detail shows how to attach a floor system in between the top and bottom of two SIP walls by hanging the joists at the top of a SIP with top mount hangers and a cap plate. Horizontal Beltline Joints Typical Details - DT-EWG-22 This detail shows three horizontal beltline joint configurations for APA panel siding at floor lines in multistory construction. Horizontal Wall Joints Typical Details - DT-EWG-23 This detail shows three horizontal joint configurations for APA panel siding — butt and flash, lap, and shiplap — each with blocking flatwise or edgewise at the joint location. I-Joist Blocking Panel Typical Details - DT-IJ-5 This detail shows the installation of PRI blocking panels between I-joists, attached to top plate with face nails for shear transfer at floor sheathing boundaries. I-Joist Cantilever Detail for Balconies Typical Details - DT-IJ-6 This detail outlines proper construction methods for cantilevered I-joist floor extensions, such as balconies. I-Joist Fire Assembly with 0.5 inch Gypsum Board Above Flange Typical Details - DT-FPF-4 This detail shows an I-joist floor assembly with 1/2" gypsum board placed above the bottom flange for fire protection per IRC Section R503. I-Joist Fire Assembly with 5/8" inch Gypsum Board Above Flange Typical Details - DT-FPF-5 This detail shows an I-joist floor assembly with 5/8" gypsum board placed above the bottom flange for fire protection per IRC Section R503. I-Joist Fire Assembly with Gypsum Board Typical Details - DT-FPF-2 This detail shows 1/2" gypsum board fastened to the bottom flange of an I-joist floor assembly for fire protection per IRC Section R702.3.1. I-Joist Fire Assembly with Gypsum Board at Bottom Flange Typical Details - DT-FPF-1 This detail shows 1/2" gypsum board or 5/8" wood structural panel installed at the bottom flange of an I-joist floor assembly for fire protection per IRC Section R702.3. I-Joist Fire Assembly with Gypsum Board at Web Holes Typical Details - DT-FPF-3 This detail shows 1/2" gypsum board installed at I-joist web holes for fire protection, shown in two configurations per IRC Section R702.3.1. I-Joist Fire Assembly with Mineral Wool Typical Details - DT-FPF-7 This detail shows an I-joist floor assembly with mineral wool insulation for fire protection per IRC Section R503. I-Joist Fire Assembly with Rockwool Safe'n'Sound Typical Details - DT-FPF-6 This detail shows an I-joist floor assembly with Rockwool Safe'n'Sound mineral wool insulation for fire protection per IRC Section R503. Installation of APA Plywood Underlayment Typical Details - DT-EWG-24 This detail shows APA plywood underlayment installation over APA Rated sheathing subfloor. Insulated Three-Stud Corner (California Corner) Typical Details - DT-AF-2 This detail shows an insulated three-stud outside corner (California corner) framing assembly. Insulated Three-Stud Corner (Inside Corner) Typical Details - DT-AF-3 This detail shows an insulated three-stud inside corner framing assembly. Intersecting Wall Connection Typical Details - DT-AF-4 This detail shows connections of intersecting single 2x top plates with steel plates and alternate lumber splice connections. OLYMPUS DIGITAL CAMERA Introduction to Lateral Design Technical Guides - X305 This publication explains how to design wood-frame buildings to withstand the lateral loads typical of high wind and seismic zones. Introduction to Wall Bracing Technical Guides - F430 This publication explains IRC-compliant wall bracing, explains why bracing is important and shows how to meet basic requirements for wall bracing in accordance with the code Ladder Junction Typical Details - DT-AF-5 This detail shows an advanced framed wall junction with single top plates and 2x ladder blocking spaced vertically at 24” O.C. for an interior wall to exterior wall connection. Large Opening Single Headers Typical Details - DT-AF-6 This detail shows the use of a single header with a width less than the wall to create more space for insulation. Lightweight or Gypsum Concrete Topping, 15/32" APA Wood Structural Panel Subfloor, 3-Dimensional Detail Typical Details - DT-FR-5 This detail shows three-dimensional floor assembly of APA wood structural panel subflooring with gypsum concrete topping over joists and Type X gypsum wallboard ceiling below. Load Carried by Flanges Typical Details - DT-SPR-11 Installation detail for supporting steel sprinkler pipes from structural framing using hanger blocks with fastening specifications for different pipe sizes and loads. Load-Bearing Interior (Chase) Wall System Typical Details - DT-FR-6 Fire-rated load bearing interior chase wall assembly with gypsum wallboard, plywood sheathing, insulation cavity, and 1-inch space between stud walls at 16- or 24-inch centers. Longitudinal Top Plate Splice Typical Details - DT-AF-7 Lumber Cantilever Detail for Balconies Typical Details - DT-IJ-7 This detail outlines a construction method for balconies using cantilevered lumber extensions attached to I-joists at their back span. Main and Side Members Typical Details - DT-SPR-12 This detail shows fastener connection between main member (last member penetrated) and side member (first member penetrated) in wood construction. Method ABW – Alternate Braced Wall Typical Details - DT-WB-2 This detail shows the alternate braced wall bracing method and its requirements including sheathing fastening, framing requirements, and foundation anchorage. Method CS-PF - Continuously Sheathed Portal Frame Panel Construction Typical Details - DT-WB-4 This detail shows the wall bracing method continuously sheathed portal frame and its requirements including anchorage, minimum member sizes, and sheathing attachment. Method PFG – Intermittent Portal Frame at Garage Door Openings in SDC A, B and C Typical Details - DT-WB-7 This detail shows the wall bracing method portal frame at a garage and its requirements including sheathing attachment, minimum member sizes, and anchorage. Method PFH – Intermittent Portal Frame with Hold Down Typical Details - DT-WB-9 This detail shows the wall bracing method portal frame with hold down and its requirements including minimum framing sizes, sheathing attachment, hold-downs, and anchorage. Minimum 1/2" APA Rated Siding Exterior Plywood, 1" Rigid Foam Insulation Sheathing; Exterior Finish-Elastomeric Coating, 1" Rigid Foam Insulation Sheathing, Minimum 1/2" APA Rated Sheathing Exposure 1 Plywood Typical Details - DT-FR-7 Fire-rated wall assembly of two UL-rated configurations (U330 and U335) with different exterior finishes over wood framing with mineral wool or glass fiber insulation. Minimum 3/8" APA Rated Siding Exterior Plywood Typical Details - DT-FR-8 This detail shows fire-rated wall assembly detail of 3/8" APA rated plywood siding over Type X gypsum wallboard with optional insulation on 2x4 studs at 16" on center. **Please note this image may have been edited or manipulated to enhance visual quality** Nail-Base Sheathing for Siding and Trim Attachment Construction Guide Technical Guides - Q250 Determine the type and spacing of siding fasteners to meet building code requirements when using wood structural panel sheathing as a nail base (also called nailable sheathing) Noise-Resistant Floor Assembly Typical Details - DT-EWG-26 This detail shows noise-resistant floor/ceiling assembly using APA Rated sheathing subfloor, lightweight concrete topping, resilient channels, and gypsum wallboard. Noise-Resistant Party Wall Typical Details - DT-EWG-27 This detail shows a noise-resistant wall assembly in plan view using staggered 2x4 studs on 2x6 plates with APA Rated sheathing and gypsum wallboard to reduce sound transmission.