Technical Document Library
Research-Backed Guidance for Every Project
Research-Backed Guidance for Every Project
Product Guide
- X440
This product guide provides an overview of APA trademarked glulam and discusses design considerations, applications and specification
Data File
- L335
This publication provides recommendations for the installation and preparation of underlayment under finish flooring in residential and light commercial applications
Builder Tip
- N335
This publication provides step-by-step instructions for roof sheathing installation
Technical Guides
- Q705
This publication provides simple steps to proper installation that ensures glulam beams perform as designed.
Builder Tip
- F455
This publication describes best practices for storage and installation of glued laminated timber (glulam).
Builder Tip
- R540
This publication provides recommendations for storage and handling of glulam beams.
Builder Tip
- R340
This publication provides an overview of selection, handling, installation and fastening of APA plywood underlayment.
Excerpt
- E30X-GL
This publication is an excerpt from the APA Engineered Wood Construction Guide, providing a description and specification recommendations for glued laminated timber (glulam)
Technical Note
- V700
This publication is a supplement to APA S560, providing an analytical tool in situations when horizontal holes exceeding the prescriptive guidance in APA S560 are necessary
Technical Guides
- C415
This publication contains span tables for glulam floor beams in residential construction, tables for substituting glulam for steel beams and design details.
Technical Guides
- C410
This publication provides connection details and installation recommendations for glulam in residential garage door framing.
Typical Details
- DT-EWG-24
This detail shows APA plywood underlayment installation over APA Rated sheathing subfloor.
Construction Guide
- T300
This publication shows correct connections and common connection errors involving glued laminated (glulam) timbers
Typical Details
- DT-IJ-4
This detail shows I-Joists with top mount hangers supported by a multi-ply structural composite lumber (SCL) beam. This detail is similar for a glulam beam with face mount hangers.
Technical Guides
- X450
Describes the selection, specification, design considerations and allowable load tables for APA-trademarked glulam used in residential headers, floor beams and roof beams.
Technical Note
- Y110
This publication clarifies the distinction between appearance considerations and structural properties of glulam timbers and appearance classifications of glulam members.
Typical Details
- DT-BB-19
This detail shows z-flashing installation at horizontal joint between APA panel siding.
Technical Note
- S550
This publication discusses how camber reduces the adverse effects of beam deflection
Technical Note
- J745_SUP
This publication is a supplement to Technical Note: Sprinkler Pipe Installation for APA Performance Rated I-Joists, Form J745, with sprinkler pipe installation design details.
Technical Note
- T350
This publication discusses how to minimize the risk of future wood flooring problems when moisture at the jobsite is an issue
Technical Note
- Y245
This publication describes the natural fire resistance of glulam beams and columns and provides fire endurance calculation methods
Typical Details
- DT-FR-9
This detail shows cross-section of a one-hour fire-rated glulam beam layup configuration with compression lams at top, core lams in center, and tension lams at bottom.
Technical Topic
- TT-130
This publication provides a method for garage door installation with back-hangs that are attached to the bottom flange of residential I-joists with lag screws.
Data File
- Q370
This publication describes recommended wall construction methods for the installation of stucco exterior finish over structural wood panel wall sheathing
Typical Details
- DT-EWG-13
This detail shows APA Rated vertical panel siding applied directly to wall framing in an APA Sturd-I-Wall system with weather-resistive barrier.
Technical Topic
- TT-108
This publication clarifies the intent of the California Building Code exemption for special inspection on glulam outlined in Section 1705.5.4
ESR Joint Evaluation Report - ESR-1940
Canfor, Western Forest Products
Typical Details
- DT-EWG-12
This detail shows APA Rated horizontal panel siding applied directly to wall framing in an APA Sturd-I-Wall system.
Technical Note
- J745
This publication provides guidance on attachment of steel and CPVC sprinkler systems to APA Performance Rated I-Joists.
Technical Topic
- TT-135
Provides recommendations for hole size and segment length for glulam rim board for situations where holes are not specified in the construction documents or shop drawings.
Case Studies
- R135
This case study discusses how glulam beams reduced costs and streamlined installation on a 5,200 square foot custom Colorado home.
Typical Details
- DT-GB-8
This detail shows connection of glulam beam bearing on solid-sawn post or glulam column using steel post cap at end wall condition.
Typical Details
- DT-GB-1
This detail shows glulam beam bearing at an end wall. The beam is supported by trimmer studs and secured to the king stud with 16d nails.
Typical Details
- DT-GB-3
This detail shows a glulam beam connection to an end wall with I-joists bearing on the beam.
Typical Details
- DT-GB-9
This detail shows a steel tie plate connection for a glulam beam bearing on a wood support at an end condition.
Typical Details
- DT-GB-11
This detail shows two connection options for a continuous glulam floor beam bearing on a wood support.
Typical Details
- DT-GB-12
This detail shows I-joists bearing on a glulam floor beam with face nail connections and blocking not shown for clarity.
Typical Details
- DT-GB-14
This detail shows a cross-section of sawn lumber floor joists secured by toe nails supported by a glulam beam.
Typical Details
- DT-GB-2
This detail shows a glulam beam connection to an end wall with flush floor joists or I-joists connected to the beam.
Typical Details
- DT-GH-1
This detail shows a connection of a garage door header at and end wall where a glulam beam is connected to a king stud with nails.
Typical Details
- DT-GB-6
This detail shows two glulam beams butting over a wood support, with the beams connected to the support using a steel post cap and through-bolts.
Typical Details
- DT-GB-10
This detail shows two options for connecting a continuous glulam floor beam to an intermediate steel column using either a steel post cap or steel cap plate.
Typical Details
- DT-GH-2
This detail shows a connection of a garage door header and an end wall using a steel plate fastened to a solid wood post, glulam column or studs.
Case Studies
- S125
This case study discusses how glulam beams and wood structural panel shear walls were used to construct a California apartment complex on budget.
Case Studies
- S110
This case study discusses the use of hybrid trusses combining glulam arches, glulam purlins and steel bottom chords at the Buffalo Sabres’ practice ice rinks.
Standards
- ANSI 117-2025
This ANSI Standard provides information for the design of structural glued laminated timber (glulam), reference values for glulam design and specific layup requirements.
Technical Topic
- TT-033
This publication discusses recommendations and exceptions for finishing glulam manufactured entirely from solid-sawn lumber.
Typical Details
- DT-EWG-21
This detail shows a heavy timber roof construction assembly using APA Rated Sturd-I-Floor T&G panels over structural glulam or solid timber beams with built-up roofing.
Typical Details
- DT-EWG-35
This detail shows four connection methods for flat roof systems: to wood I-joists, open-web parallel-chord wood trusses, steel bar joists with wood nailer and glulam beams.
Typical Details
- DT-FR-24
This detail shows a heavy timber roof assembly with wood structural panels, featuring heavy timber or glulam beams supporting tongue-and-groove wood decking with built-up roofing.
Technical Topic
- TT-127
This publication provides a summary of results of an APA/USDA Forest Product Laboratory pilot test program examining structural properties of Fire-Retardant Treated glulam.
Technical Guides
- F450
This publication addresses common concerns related to checking in glulam and explains how to evaluate if the check effects the glulam’s strength
Technical Note
- R280
This publication provides specification and installation recommendations for panel subfloors to be used under hardwood flooring
Case Studies
- R145
This case study discusses how glulam beams, planks, girders and columns were used to structurally and aesthetically restore the historic Appleton Mills complex in Lowell, MA.
Technical Note
- R475
This publication discusses checking in glulam beams and includes a flowchart and equations for determining allowable check size
Technical Note
- S560
This publication provides guidance for notching and drilling on glulam when the end notching and drilling of horizontal though-thickness holes cannot be avoided
Technical Topic
- TT-104
This publication explains the difference between apparent modulus of elasticity (MOE) and shear-free MOE in glulam beams
Technical Guides
- S475
This publication provides recommended design load tables for glulam beam roof and floor applications
Case Studies
- C115
This case study discusses how a glulam roof structure provided decay resistance, seismic performance and cost savings for a municipal water reservoir in California.
Case Studies
- V135
This case study discusses how CLT and glulam helped First United Bank achieve construction and energy efficiencies.
Technical Note
- Y260
Explains how glulam shrinks or swells as moisture content changes, gives shrinkage coefficients by species, and shows how to tell moisture movement from tolerance issues.
Case Studies
- R130
This case study discusses the Brelsford WSU visitor center’s use of several engineered wood products, including CLT and glulam.
Technical Note
- S580
This publication provides a summary of preservatives, treatment recommendations, use, handling and finishing tips for preservative-treated glulam beams
Technical Topic
- TT-007
This publication recommends three methods for the installation of a wood floor system over a concrete slab: sleepers, rigid foam or direct.
Typical Details
- DT-IJ-1
This detail outlines backer block installation for single and double I-joist headers.
Case Studies
- S120
This publication discusses how glulam framing and engineered wood helped Portland’s One North development achieve energy efficiency and sustainability.
Typical Details
- DT-BB-8
This detail shows two-piece flashing installation at wall penetration.
Case Studies
- Q125
This case study explains how glulam beams were used to replace the flooring system of the historic Audrian Building, enabling the building to support multi-ton vintage automobiles.
Case Studies
- R115
This case study discusses how glulam beams solved complex structural challenges on a pentagon-shaped coastal house.
Builder Tip
- K310
Describes installation techniques for plywood and OSB roof sheathing and roof ventilation techniques that will help minimize the potential for buckling of asphalt shingles
Typical Details
- DT-SPR-2
This detail shows ceiling flange hanger installation for supporting steel sprinkler system pipes from engineered wood ceiling joists.
Typical Details
- DT-SPR-16
This detail illustrates a seismic sway brace blocking configuration, showing the installation of perpendicular diagonal bracing for I-joist floor systems.
Typical Details
- DT-SPR-17
This detail shows seismic bracing web blocking and cross member installation for I-joists to resist loads perpendicular to joist direction.
Typical Details
- DT-BB-14
This detail shows six-step sequential window installation when using building paper.
Typical Details
- DT-BB-15
This detail shows six-step sequential window installation detail of proper order of water-resistive barrier.
Case Studies
- U115
This case study discusses how CLT panels and glulam framing delivered cost savings, a faster schedule and sustainability benefits for First Tech Federal Credit Union.
Case Studies
- R110
This case study explains how glulam beams and Douglas-fir columns helped the Jackson Hole Airport meet strict height limits and seismic demands.
Case Studies
- N115
This case study discusses how curved glulam beams enabled dramatic design, seismic resilience and cost effectiveness for the LeMay Car Museum in Tacoma, Washington.
Technical Topic
- TT-132
Recommendations for cutting holes in I-joists, LVL and glulam for electrical cables in compliance with the National Electric Code (NEC) and International Residential Code (IRC)
Technical Topic
- TT-092
This publication describes revisions of the 2016 American Wood Protection Association (AWPA) U1 standard that are related to structural glued laminated timber (glulam)
Technical Guides
- C800
Describes common engineered wood products: plywood, oriented strand board (OSB), I-joist, glued laminated timber (glulam), structural composite lumber (SCL) and rim board.
Case Studies
- S115
This case study explains how glulam beams and engineered wood products shaped 2125 Franklin, a 735-bedroom mixed-use student housing building near the University of Oregon.
Typical Details
- DT-IJ-3
This detail shows installation of backer and filler blocks for a double I-joist header supporting a stair stringer that is attached with a framing anchor.
Construction Guide
- R305
This publication provides specification recommendations for plywood and OSB roof systems and installation recommendations for panel roofs
Technical Guides
- T625
This publication provides design and fastening recommendations for installation of wood structural panels over metal framing in floors, walls and roofs.
Case Studies
- X170
This case study discusses how the Las Ventanas affordable housing project used glulam, LVL, OSB and FTAO design principles to cut costs and streamline construction.
Technical Note
- C465
This publication provides installation recommendations and test results for energy-saving APA Sturd-I-Wall construction
Builder Tip
- S300
This publication describes how to reduce nail pops through recommended fastener selection and installation
Typical Details
- DT-SPR-11
Installation detail for supporting steel sprinkler pipes from structural framing using hanger blocks with fastening specifications for different pipe sizes and loads.
Typical Details
- DT-SPR-14
This detail shows installation of an offset eye-socket hanger supporting a 4-inch steel sprinkler pipe with filler block bearing and fastening requirements.
Typical Details
- DT-SPR-15
This detail shows two installation options for seismic sway brace blocking attached parallel to I-joist webs with blocking on one or both sides.
Technical Topic
- TT-083
This publication provides installation guidelines for hip-roof panel applications on trusses spaced 24 in. o.c. that address serviceability issues and improve performance
Typical Details
- DT-IJ-5
This detail shows the installation of PRI blocking panels between I-joists, attached to top plate with face nails for shear transfer at floor sheathing boundaries.
Typical Details
- DT-IJ-8
This detail shows PRI blocking installation. It outlines where blocking is required, how to attach blocking and floor joists to a double top plate, and vertical load capacities.
Typical Details
- DT-IJ-10
This detail shows the installation of APA rim board to floor joists and a double top plate, specifically noting vertical capacity and shear transfer nailing.
Typical Details
- DT-IJ-11
This detail shows installation of a sheathing reinforcement on cantilevered I-joists at a vertical building offset and specifies a reinforcement for one side of the I-joist.
Typical Details
- DT-IJ-12
This detail shows installation of a sheathing reinforcement on cantilevered I-joists at a vertical building offset and specifies reinforcement for two sides of the I-joist.
Typical Details
- DT-IJ-13
This detail shows installation of single or double I-joists to a top plate along an exterior wall and where backer blocks would be required for siding attachment.
Construction Guide
- R300
Provides specification recommendations for plywood and OSB floor systems, the APA Glued Floor System and installation recommendations for panel subflooring and underlayment
Typical Details
- DT-SPR-5
This detail shows two installation options for face-mounting CPVC sprinkler pipe hangers to wood blocking using either sheet metal screws or nail-and-block combinations.
Typical Details
- DT-SPR-6
This detail shows offset hanger installation for CPVC sprinkler system pipes showing two attachment options using backing nuts or sheet metal screws with lumber blocking.
Typical Details
- DT-SPR-7
This detail shows proper installation of a CPVC sprinkler system pipe hanger through an I-joist web bore, with maximum diameter and load requirements per NFPA 13.
Typical Details
- DT-SPR-13
This detail shows steel angle trapeze hanger system for supporting CPVC or steel sprinkler pipes from wood joists per NFPA 13 requirements with two installation options.
Typical Details
- DT-EWG-8
This detail shows APA Rated Sturd-I-Floor panel installation at 16", 20", or 24" o.c. joist spacing with tongue-and-groove edges over a floor framing system.
Typical Details
- DT-EWG-9
This detail shows APA Rated Sturd-I-Floor panel installation at 32" or 48" o.c. joist spacing with tongue-and-groove joints over a crawl space floor framing system.
Typical Details
- DT-SIP-4
This detail shows installation of a floor system between the top and bottom of two SIP walls with the joists directly on top of the SIP with a cap plate and rim board end closure.
Construction Guide
- Z725
This publication discusses span ratings, installation details, cantilever designs, architectural specifications and engineering design properties for APA Performance Rated I-Joists
Typical Details
- DT-GB-13
This detail shows two floor joist flush connections options: one face mounted hanger and one top mounted hanger.
Typical Details
- DT-AF-6
This detail shows the use of a single header with a width less than the wall to create more space for insulation.
APA Product Reports - PR-E740
CLT, Glulam:
APA Product Reports - PR-L275
Glulam:
APA Product Reports - PR-L297
Glulam:
APA Product Reports - PR-L321
Glulam:
Standards
- ANSI 405-2023
This ANSI standard provides minimum requirements to evaluate adhesives for use in structural glued laminated timber. This document is a revision of ANSI 405-2018.
APA Product Reports - PR-L263
Glulam:
APA Product Reports - PR-L269
Glulam, Rim Board:
APA Product Reports - PR-L282
Glulam:
APA Product Reports - PR-L326
Glulam:
Data File
- Y240
This publication provides information on member sizes and layup, design stresses, column design equations and design tables and examples.