Technical Document Library
Research-Backed Guidance for Every Project
Research-Backed Guidance for Every Project
Product Guide
- X440
This product guide provides an overview of APA trademarked glulam and discusses design considerations, applications and specification
Data File
- L335
This publication provides recommendations for the installation and preparation of underlayment under finish flooring in residential and light commercial applications
Builder Tip
- N335
This publication provides step-by-step instructions for roof sheathing installation
Technical Guides
- Q705
This publication provides simple steps to proper installation that ensures glulam beams perform as designed.
Builder Tip
- F455
This publication describes best practices for storage and installation of glued laminated timber (glulam).
Builder Tip
- R540
This publication provides recommendations for storage and handling of glulam beams.
Builder Tip
- R340
This publication provides an overview of selection, handling, installation and fastening of APA plywood underlayment.
Excerpt
- E30X-GL
This publication is an excerpt from the APA Engineered Wood Construction Guide, providing a description and specification recommendations for glued laminated timber (glulam)
Technical Note
- V700
This publication is a supplement to APA S560, providing an analytical tool in situations when horizontal holes exceeding the prescriptive guidance in APA S560 are necessary
Technical Guides
- C415
This publication contains span tables for glulam floor beams in residential construction, tables for substituting glulam for steel beams and design details.
Technical Guides
- C410
This publication provides connection details and installation recommendations for glulam in residential garage door framing.
Typical Details
- DT-EWG-24
This detail shows APA plywood underlayment installation over APA Rated sheathing subfloor.
Construction Guide
- T300
This publication shows correct connections and common connection errors involving glued laminated (glulam) timbers
Typical Details
- DT-IJ-4
This detail shows I-Joists with top mount hangers supported by a multi-ply structural composite lumber (SCL) beam. This detail is similar for a glulam beam with face mount hangers.
Technical Guides
- X450
Describes the selection, specification, design considerations and allowable load tables for APA-trademarked glulam used in residential headers, floor beams and roof beams.
Technical Note
- Y110
This publication clarifies the distinction between appearance considerations and structural properties of glulam timbers and appearance classifications of glulam members.
Typical Details
- DT-BB-19
This detail shows z-flashing installation at horizontal joint between APA panel siding.
Technical Note
- S550
This publication discusses how camber reduces the adverse effects of beam deflection
Technical Note
- J745_SUP
This publication is a supplement to Technical Note: Sprinkler Pipe Installation for APA Performance Rated I-Joists, Form J745, with sprinkler pipe installation design details.
Technical Note
- T350
This publication discusses how to minimize the risk of future wood flooring problems when moisture at the jobsite is an issue
Technical Note
- Y245
This publication describes the natural fire resistance of glulam beams and columns and provides fire endurance calculation methods
Typical Details
- DT-FR-9
This detail shows cross-section of a one-hour fire-rated glulam beam layup configuration with compression lams at top, core lams in center, and tension lams at bottom.
Technical Topic
- TT-130
This publication provides a method for garage door installation with back-hangs that are attached to the bottom flange of residential I-joists with lag screws.
Data File
- Q370
This publication describes recommended wall construction methods for the installation of stucco exterior finish over structural wood panel wall sheathing
Typical Details
- DT-EWG-13
This detail shows APA Rated vertical panel siding applied directly to wall framing in an APA Sturd-I-Wall system with weather-resistive barrier.
Technical Topic
- TT-108
This publication clarifies the intent of the California Building Code exemption for special inspection on glulam outlined in Section 1705.5.4
ESR Joint Evaluation Report - ESR-1940
Canfor, Western Forest Products
Typical Details
- DT-EWG-12
This detail shows APA Rated horizontal panel siding applied directly to wall framing in an APA Sturd-I-Wall system.
Technical Note
- J745
This publication provides guidance on attachment of steel and CPVC sprinkler systems to APA Performance Rated I-Joists.
Technical Topic
- TT-135
Provides recommendations for hole size and segment length for glulam rim board for situations where holes are not specified in the construction documents or shop drawings.
Case Studies
- R135
This case study discusses how glulam beams reduced costs and streamlined installation on a 5,200 square foot custom Colorado home.
Typical Details
- DT-GB-8
This detail shows connection of glulam beam bearing on solid-sawn post or glulam column using steel post cap at end wall condition.
Typical Details
- DT-GB-1
This detail shows glulam beam bearing at an end wall. The beam is supported by trimmer studs and secured to the king stud with 16d nails.
Typical Details
- DT-GB-3
This detail shows a glulam beam connection to an end wall with I-joists bearing on the beam.
Typical Details
- DT-GB-9
This detail shows a steel tie plate connection for a glulam beam bearing on a wood support at an end condition.
Typical Details
- DT-GB-11
This detail shows two connection options for a continuous glulam floor beam bearing on a wood support.
Typical Details
- DT-GB-12
This detail shows I-joists bearing on a glulam floor beam with face nail connections and blocking not shown for clarity.
Typical Details
- DT-GB-14
This detail shows a cross-section of sawn lumber floor joists secured by toe nails supported by a glulam beam.
Typical Details
- DT-GB-2
This detail shows a glulam beam connection to an end wall with flush floor joists or I-joists connected to the beam.
Typical Details
- DT-GH-1
This detail shows a connection of a garage door header at and end wall where a glulam beam is connected to a king stud with nails.
Typical Details
- DT-GB-6
This detail shows two glulam beams butting over a wood support, with the beams connected to the support using a steel post cap and through-bolts.
Typical Details
- DT-GB-10
This detail shows two options for connecting a continuous glulam floor beam to an intermediate steel column using either a steel post cap or steel cap plate.
Typical Details
- DT-GH-2
This detail shows a connection of a garage door header and an end wall using a steel plate fastened to a solid wood post, glulam column or studs.
Case Studies
- S125
This case study discusses how glulam beams and wood structural panel shear walls were used to construct a California apartment complex on budget.
Case Studies
- S110
This case study discusses the use of hybrid trusses combining glulam arches, glulam purlins and steel bottom chords at the Buffalo Sabres’ practice ice rinks.
Standards
- ANSI 117-2025
This ANSI Standard provides information for the design of structural glued laminated timber (glulam), reference values for glulam design and specific layup requirements.
Technical Topic
- TT-033
This publication discusses recommendations and exceptions for finishing glulam manufactured entirely from solid-sawn lumber.
Typical Details
- DT-EWG-21
This detail shows a heavy timber roof construction assembly using APA Rated Sturd-I-Floor T&G panels over structural glulam or solid timber beams with built-up roofing.
Typical Details
- DT-EWG-35
This detail shows four connection methods for flat roof systems: to wood I-joists, open-web parallel-chord wood trusses, steel bar joists with wood nailer and glulam beams.
Typical Details
- DT-FR-24
This detail shows a heavy timber roof assembly with wood structural panels, featuring heavy timber or glulam beams supporting tongue-and-groove wood decking with built-up roofing.
Technical Topic
- TT-127
This publication provides a summary of results of an APA/USDA Forest Product Laboratory pilot test program examining structural properties of Fire-Retardant Treated glulam.
Technical Guides
- F450
This publication addresses common concerns related to checking in glulam and explains how to evaluate if the check effects the glulam’s strength
Technical Note
- R280
This publication provides specification and installation recommendations for panel subfloors to be used under hardwood flooring
Case Studies
- R145
This case study discusses how glulam beams, planks, girders and columns were used to structurally and aesthetically restore the historic Appleton Mills complex in Lowell, MA.
Technical Note
- R475
This publication discusses checking in glulam beams and includes a flowchart and equations for determining allowable check size
Technical Note
- S560
This publication provides guidance for notching and drilling on glulam when the end notching and drilling of horizontal though-thickness holes cannot be avoided
Technical Topic
- TT-104
This publication explains the difference between apparent modulus of elasticity (MOE) and shear-free MOE in glulam beams
Technical Guides
- S475
This publication provides recommended design load tables for glulam beam roof and floor applications
Case Studies
- C115
This case study discusses how a glulam roof structure provided decay resistance, seismic performance and cost savings for a municipal water reservoir in California.
Case Studies
- V135
This case study discusses how CLT and glulam helped First United Bank achieve construction and energy efficiencies.
Technical Note
- Y260
Explains how glulam shrinks or swells as moisture content changes, gives shrinkage coefficients by species, and shows how to tell moisture movement from tolerance issues.
Case Studies
- R130
This case study discusses the Brelsford WSU visitor center’s use of several engineered wood products, including CLT and glulam.
Technical Note
- S580
This publication provides a summary of preservatives, treatment recommendations, use, handling and finishing tips for preservative-treated glulam beams
Technical Topic
- TT-007
This publication recommends three methods for the installation of a wood floor system over a concrete slab: sleepers, rigid foam or direct.
Typical Details
- DT-IJ-1
This detail outlines backer block installation for single and double I-joist headers.
Case Studies
- S120
This publication discusses how glulam framing and engineered wood helped Portland’s One North development achieve energy efficiency and sustainability.
Typical Details
- DT-BB-8
This detail shows two-piece flashing installation at wall penetration.
Case Studies
- Q125
This case study explains how glulam beams were used to replace the flooring system of the historic Audrian Building, enabling the building to support multi-ton vintage automobiles.
Case Studies
- R115
This case study discusses how glulam beams solved complex structural challenges on a pentagon-shaped coastal house.
Builder Tip
- K310
Describes installation techniques for plywood and OSB roof sheathing and roof ventilation techniques that will help minimize the potential for buckling of asphalt shingles
Typical Details
- DT-SPR-2
This detail shows ceiling flange hanger installation for supporting steel sprinkler system pipes from engineered wood ceiling joists.
Typical Details
- DT-SPR-16
This detail illustrates a seismic sway brace blocking configuration, showing the installation of perpendicular diagonal bracing for I-joist floor systems.
Typical Details
- DT-SPR-17
This detail shows seismic bracing web blocking and cross member installation for I-joists to resist loads perpendicular to joist direction.
Typical Details
- DT-BB-14
This detail shows six-step sequential window installation when using building paper.
Typical Details
- DT-BB-15
This detail shows six-step sequential window installation detail of proper order of water-resistive barrier.
Case Studies
- U115
This case study discusses how CLT panels and glulam framing delivered cost savings, a faster schedule and sustainability benefits for First Tech Federal Credit Union.
Case Studies
- R110
This case study explains how glulam beams and Douglas-fir columns helped the Jackson Hole Airport meet strict height limits and seismic demands.
Case Studies
- N115
This case study discusses how curved glulam beams enabled dramatic design, seismic resilience and cost effectiveness for the LeMay Car Museum in Tacoma, Washington.
Technical Topic
- TT-132
Recommendations for cutting holes in I-joists, LVL and glulam for electrical cables in compliance with the National Electric Code (NEC) and International Residential Code (IRC)
Technical Topic
- TT-092
This publication describes revisions of the 2016 American Wood Protection Association (AWPA) U1 standard that are related to structural glued laminated timber (glulam)
Technical Guides
- C800
Describes common engineered wood products: plywood, oriented strand board (OSB), I-joist, glued laminated timber (glulam), structural composite lumber (SCL) and rim board.
Case Studies
- S115
This case study explains how glulam beams and engineered wood products shaped 2125 Franklin, a 735-bedroom mixed-use student housing building near the University of Oregon.
Typical Details
- DT-IJ-3
This detail shows installation of backer and filler blocks for a double I-joist header supporting a stair stringer that is attached with a framing anchor.
Construction Guide
- R305
This publication provides specification recommendations for plywood and OSB roof systems and installation recommendations for panel roofs
Technical Guides
- T625
This publication provides design and fastening recommendations for installation of wood structural panels over metal framing in floors, walls and roofs.
Case Studies
- X170
This case study discusses how the Las Ventanas affordable housing project used glulam, LVL, OSB and FTAO design principles to cut costs and streamline construction.
Technical Note
- C465
This publication provides installation recommendations and test results for energy-saving APA Sturd-I-Wall construction
Builder Tip
- S300
This publication describes how to reduce nail pops through recommended fastener selection and installation
Typical Details
- DT-SPR-11
Installation detail for supporting steel sprinkler pipes from structural framing using hanger blocks with fastening specifications for different pipe sizes and loads.
Typical Details
- DT-SPR-14
This detail shows installation of an offset eye-socket hanger supporting a 4-inch steel sprinkler pipe with filler block bearing and fastening requirements.
Typical Details
- DT-SPR-15
This detail shows two installation options for seismic sway brace blocking attached parallel to I-joist webs with blocking on one or both sides.
Technical Topic
- TT-083
This publication provides installation guidelines for hip-roof panel applications on trusses spaced 24 in. o.c. that address serviceability issues and improve performance
Typical Details
- DT-IJ-5
This detail shows the installation of PRI blocking panels between I-joists, attached to top plate with face nails for shear transfer at floor sheathing boundaries.
Typical Details
- DT-IJ-8
This detail shows PRI blocking installation. It outlines where blocking is required, how to attach blocking and floor joists to a double top plate, and vertical load capacities.
Typical Details
- DT-IJ-10
This detail shows the installation of APA rim board to floor joists and a double top plate, specifically noting vertical capacity and shear transfer nailing.
Typical Details
- DT-IJ-11
This detail shows installation of a sheathing reinforcement on cantilevered I-joists at a vertical building offset and specifies a reinforcement for one side of the I-joist.
Typical Details
- DT-IJ-12
This detail shows installation of a sheathing reinforcement on cantilevered I-joists at a vertical building offset and specifies reinforcement for two sides of the I-joist.
Typical Details
- DT-IJ-13
This detail shows installation of single or double I-joists to a top plate along an exterior wall and where backer blocks would be required for siding attachment.
Construction Guide
- R300
Provides specification recommendations for plywood and OSB floor systems, the APA Glued Floor System and installation recommendations for panel subflooring and underlayment
Typical Details
- DT-SPR-5
This detail shows two installation options for face-mounting CPVC sprinkler pipe hangers to wood blocking using either sheet metal screws or nail-and-block combinations.
Typical Details
- DT-SPR-6
This detail shows offset hanger installation for CPVC sprinkler system pipes showing two attachment options using backing nuts or sheet metal screws with lumber blocking.
Typical Details
- DT-SPR-7
This detail shows proper installation of a CPVC sprinkler system pipe hanger through an I-joist web bore, with maximum diameter and load requirements per NFPA 13.
Typical Details
- DT-SPR-13
This detail shows steel angle trapeze hanger system for supporting CPVC or steel sprinkler pipes from wood joists per NFPA 13 requirements with two installation options.
Typical Details
- DT-EWG-8
This detail shows APA Rated Sturd-I-Floor panel installation at 16", 20", or 24" o.c. joist spacing with tongue-and-groove edges over a floor framing system.
Typical Details
- DT-EWG-9
This detail shows APA Rated Sturd-I-Floor panel installation at 32" or 48" o.c. joist spacing with tongue-and-groove joints over a crawl space floor framing system.
Typical Details
- DT-SIP-4
This detail shows installation of a floor system between the top and bottom of two SIP walls with the joists directly on top of the SIP with a cap plate and rim board end closure.
Construction Guide
- Z725
This publication discusses span ratings, installation details, cantilever designs, architectural specifications and engineering design properties for APA Performance Rated I-Joists
Typical Details
- DT-GB-13
This detail shows two floor joist flush connections options: one face mounted hanger and one top mounted hanger.
Typical Details
- DT-AF-6
This detail shows the use of a single header with a width less than the wall to create more space for insulation.
APA Product Reports - PR-E740
CLT, Glulam:
APA Product Reports - PR-L275
Glulam:
APA Product Reports - PR-L297
Glulam:
APA Product Reports - PR-L321
Glulam:
Standards
- ANSI 405-2023
This ANSI standard provides minimum requirements to evaluate adhesives for use in structural glued laminated timber. This document is a revision of ANSI 405-2018.
APA Product Reports - PR-L263
Glulam:
APA Product Reports - PR-L269
Glulam, Rim Board:
APA Product Reports - PR-L282
Glulam:
APA Product Reports - PR-L326
Glulam:
Data File
- Y240
This publication provides information on member sizes and layup, design stresses, column design equations and design tables and examples.
Standards
- ANSI A190.1-2022
This ANSI Standard contains requirements for the manufacture and quality control of structural glued laminated timber.
Standards
- ANSI/APA PRS 610.1-2023
This standard covers the manufacturing, qualification, quality assurance, design and installation requirements for performance-rated structural insulated panels used in walls
Builder Tip
- Q300
This publication describes how to prevent floor complaints and callbacks with proper floor sheathing installation
Technical Guides
- E30
This publication provides a comprehensive overview of engineered wood construction systems for residential, commercial and industrial buildings
Excerpt
- E30X-RB
This publication is an excerpt from the APA Engineered Wood Construction Guide, providing guidance on selecting and specifying rim board
Excerpt
- E30X-FC
This publication is an excerpt from the APA Engineered Wood Construction Guide, providing information about floor framing and wood structural panel products
Standards
- ANSI/APA PRR 410
This standard provides requirements and test methods for qualification and quality assurance for performance rated engineered wood rim board.
Case Studies
- X175
This publication discusses how a California nonprofit incorporated engineered wood into an affordable housing complex to keep costs low and create an inclusive community
Technical Guides
- W305
This publication is a guide to cost-effective fire-rated wood and wood structural panel systems that meet code requirements
Technical Note
- J330
This publication addresses concerns related to formaldehyde in engineered wood products and explains their exemption from leading formaldehyde emission standards and regulations.
Market Analysis Reports
- QPRO-26
The APA Quarterly Production Report delivers comprehensive, up-to-date data on North American structural wood panel and engineered wood product markets
Market Analysis Reports
- QPRO-26
The APA Quarterly Production Report delivers comprehensive, up-to-date data on North American structural wood panel and engineered wood product markets
Market Analysis Reports
- QPRO-26
The APA Quarterly Production Report delivers comprehensive, up-to-date data on North American structural wood panel and engineered wood product markets
Technical Topic
- TT-126
Publication answers common questions about fire-protective coatings. Certification and inspection of products with fire-protective coatings are generally outside the scope of APA.
Case Studies
- W170
This case study discusses two Washington school districts that creatively leveraged the benefits of exposed wood products in newly constructed schools.
Case Studies
- Z110
This case study discusses how a Sprouts grocery store used engineered wood instead of steel for the roof system to solve supply chain challenges and reduce their carbon footprint.
Green Verification Report - GR-L343
Glulam, Rim Board:
Specification Guide
- SP-1103
This publication provides an overview of the APA trademark and includes a sample specification for APA Rated Sheathing.
Technical Guides
- D710
This publication includes recommended construction details for I-joists in roof applications.
Technical Topic
- TT-078
This publication provides suggested I-joist blocking details, which may be used when local codes require prescriptive blocking in the space adjacent to starter joists or rim board.
Technical Topic
- TT-006
This publication describes Tile Council of North America (TCNA) specifications for wood structural panel floor systems under ceramic tile, tested in accordance with ASTM C627
Typical Details
- DT-SPR-1
This detail shows angle bracket hanger assembly for supporting steel sprinkler pipe from wood structural members using blocking and optional fastening methods.
System Report
- SR-101
This report discusses using wood structural panels to resist uplift from wind, including resistance to lateral shear forces and wind pressure perpendicular to the wall
Technical Note
- F410
This publication describes mechanism and construction features that contribute to siding buckling
Typical Details
- DT-SPR-3
This detail shows a coach screw hanger assembly for supporting steel sprinkler pipe from wood framing using filler blocks and sheet metal screws or nails.
Typical Details
- DT-SPR-4
This detail shows double offset CPVC sprinkler pipe hanger assembly using 2x4 blocking with sheet metal screws or nails, supporting 3" maximum diameter pipe per NFPA 13.
Typical Details
- DT-SPR-8
This detail shows proper bolt spacing requirements including loaded edge distance, unloaded edge distance, end distance, and spacing between rows of bolts.
Typical Details
- DT-SPR-9
This detail shows eye rod hanger for supporting steel sprinkler pipes from wood framing using filler blocks and sheet metal screws or nails per NFPA 13 requirements.
Typical Details
- DT-SPR-12
This detail shows fastener connection between main member (last member penetrated) and side member (first member penetrated) in wood construction.
Typical Details
- DT-IJ-14
This detail shows solid vertical blocking in a floor cavity, next to an I-joist, to properly transfer load from above to bearing below.
Specification Guide
- SP-1101
This publication provides an overview of the APA trademark and includes a sample specification for APA Rated Sturd-I-Floor (OSB).
Specification Guide
- SP-1102
This publication provides an overview of the APA trademark and includes a sample specification for APA Rated Sturd-I-Floor (Plywood).
Customer Service Tip
- W503
This publication discusses the causes, prevention and remedial treatment for floor sheathing ridging.
Technical Topic
- TT-060
Provides a recommendation for foam plastic roof insulation over minimum Performance Category 15/32 engineered wood panels that meet the 15-minute thermal barrier requirement
Builder Tip
- Q350
This publication describes recommended finishes and application recommendations for APA Rated Siding.
Typical Details
- DT-FTO-1
This detail shows the layout of a force transfer around opening shear wall.
Typical Details
- DT-IJ-6
This detail outlines proper construction methods for cantilevered I-joist floor extensions, such as balconies.
Typical Details
- DT-IJ-7
This detail outlines a construction method for balconies using cantilevered lumber extensions attached to I-joists at their back span.
Typical Details
- DT-EWG-31
This detail shows APA Rated sheathing panels installed as an open soffit on exposed roof rafters with weather-protected edges.
Typical Details
- DT-EWG-32
This detail shows a prefabricated APA wood structural panel roof assembly with purlins installed perpendicular to the supports.
Typical Details
- DT-EWG-33
This detail shows a hold down anchor assembly connecting a shear wall to a concrete foundation to resist overturning forces.
Typical Details
- DT-BB-6
This detail shows sill flashing detail at sliding glass door of pan flashing counter-flashing deck flashing and water-resistive barrier.
Typical Details
- DT-SIP-7
This detail outlines the construction of an eave using a SIP, highlighting proper flashing, sealant, and roofing materials.
Typical Details
- DT-AF-16
This detail shows a two-stud inside corner framing assembly with a panelized/prefabricated wall system.
System Report
- SR-103
This publication outlines a construction solution to meet the IRC’s lateral and wind uplift load requirements using wood structural panels with raised-heel, or energy-heel, trusses
Typical Details
- DT-FR-1
This detail shows floor assembly of APA wood structural panel subfloor over plywood underlayment, building paper, and joists with gypsum wallboard ceiling below.
Typical Details
- DT-AF-1
This detail shows an alternative insulated 3-stud corner framing assembly with drywall clips to support the gypsum from one stud.
Typical Details
- DT-EWG-1
This detail shows an APA glued floor system using APA Rated Sturd-I-Floor or sheathing panels.
Typical Details
- DT-EWG-2
This detail shows APA Rated sheathing panels installed as roof decking over rafters or trusses with panel clips, asphalt or wood shingles, and proper edge and joint spacing.
Typical Details
- DT-EWG-3
This detail shows APA panel stair treads and risers installed on stringers in two configurations, using plywood, OSB, or composite panels with 8d common nail fastening.
Typical Details
- DT-EWG-4
APA Rated sheathing panels installed as subflooring over 2x joists, I-joists, or floor trusses with tongue-and-groove or blocked edges on a wood-framed floor system.
Typical Details
- DT-EWG-5
This detail shows APA Rated wall sheathing applied in two orientations- strength axis across or parallel to studs- with weather-resistive barrier and siding on a wood-framed wall.
Typical Details
- DT-EWG-6
This detail shows APA Rated lap siding installed over wood structural panel sheathing with a weather-resistive barrier on a wood-framed exterior wall assembly.
Typical Details
- DT-EWG-7
This detail shows APA Rated siding panels applied over wood structural panel sheathing with a weather-resistive barrier on a wood-framed wall assembly.
Typical Details
- DT-FR-2
This detail shows a fire-rated wall assembly using wood structural panel sheathing over studs with gypsum wallboard, fire protective membrane, and glass fiber insulation.
Typical Details
- DT-FR-3
This detail shows fire-rated exterior wall assembly with APA rated siding over sheathing, insulation, 2x4 wood framing at 16" on center and Type X gypsum wallboard interior finish.
Typical Details
- DT-FR-4
This detail shows a one-hour fire-rated wood-framed wall assembly with Type X gypsum sheathing and wallboard, optional insulation, and APA rated siding exterior finish.
Typical Details
- DT-EWG-10
This detail shows APA Rated Sturd-I-Floor 48 o.c. panels installed over a post-and-beam floor framing system with 4x4 posts, 4x girders, and tongue-and-groove panel edges.
Typical Details
- DT-SIP-1
This detail shows a SIP wall beveled to support a sloped SIP roof that are connected together with panel screws and nails. It also shows sealant, roofing material and cladding.
Typical Details
- DT-BB-2
This detail shows chimney counter flashing detail of base flashing over shingle underlayment and roof deck, with counter flashing embedded in brick mortar joint.
Typical Details
- DT-EWG-14
This detail shows brick veneer or masonry cladding installed over APA Rated wood structural panel sheathing.
Typical Details
- DT-IJ-2
This detail shows cantilevered double I-joists supporting a vertical building offset and specifies connections to the top plate, blocking panels, and Rim Board or APA WSP closure.
Typical Details
- DT-EWG-15
This detail shows a closed soffit assembly using APA rated roof sheathing and exterior panels for the closed soffit with continuous screened or louvered venting.
Typical Details
- DT-BB-1
This detail shows concrete masonry crawl space foundation.
Typical Details
- DT-EWG-16
This detail shows two energy-conserving exterior wall assemblies.
Typical Details
- DT-RH-1
This detail shows raised heel energy truss attachment to an exterior wall for additional attic insulation space.
Typical Details
- DT-BB-3
This detail shows exterior deck ledger connection to wood I-joist floor system of water-resistant flashing.
Technical Topic
- TT-133
This publication discusses buckling, fastener recommendations, surface flaking, thickness swell, linear expansion and moisture management of OSB wood structural panels
Typical Details
- DT-EWG-17
This detail shows an FM Class 1-105 rated flat roof assembly using wood structural panels over open-web trusses.
Typical Details
- DT-EWG-18
This detail shows an FM Class 1-120 rated flat roof assembly using wood structural panels over steel joists.
Typical Details
- DT-EWG-19
This detail shows an FM Class 1-135 rated flat roof assembly using wood structural panels.
Typical Details
- DT-EWG-20
This detail shows an FM Class 1-90 rated flat roof assembly using wood structural panels with foam insulation, fiberboard cover board, and built-up or modified bitumen roofing.
Typical Details
- DT-SIP-2
This detail shows roof SIPs sloped up to form a ridge and connections of the SIPs to framing members with panel screws, while also showing tape, sealant, and roofing materials.
Typical Details
- DT-SIP-3
This detail shows how to attach a floor system in between the top and bottom of two SIP walls by hanging the joists at the top of a SIP with top mount hangers and a cap plate.
Typical Details
- DT-EWG-22
This detail shows three horizontal beltline joint configurations for APA panel siding at floor lines in multistory construction.
Typical Details
- DT-EWG-23
This detail shows three horizontal joint configurations for APA panel siding — butt and flash, lap, and shiplap — each with blocking flatwise or edgewise at the joint location.
Typical Details
- DT-FPF-4
This detail shows an I-joist floor assembly with 1/2" gypsum board placed above the bottom flange for fire protection per IRC Section R503.
Typical Details
- DT-FPF-5
This detail shows an I-joist floor assembly with 5/8" gypsum board placed above the bottom flange for fire protection per IRC Section R503.
Typical Details
- DT-FPF-2
This detail shows 1/2" gypsum board fastened to the bottom flange of an I-joist floor assembly for fire protection per IRC Section R702.3.1.
Typical Details
- DT-FPF-1
This detail shows 1/2" gypsum board or 5/8" wood structural panel installed at the bottom flange of an I-joist floor assembly for fire protection per IRC Section R702.3.
Typical Details
- DT-FPF-3
This detail shows 1/2" gypsum board installed at I-joist web holes for fire protection, shown in two configurations per IRC Section R702.3.1.
Typical Details
- DT-FPF-7
This detail shows an I-joist floor assembly with mineral wool insulation for fire protection per IRC Section R503.
Typical Details
- DT-FPF-6
This detail shows an I-joist floor assembly with Rockwool Safe'n'Sound mineral wool insulation for fire protection per IRC Section R503.
Typical Details
- DT-AF-2
This detail shows an insulated three-stud outside corner (California corner) framing assembly.
Typical Details
- DT-AF-3
This detail shows an insulated three-stud inside corner framing assembly.
Typical Details
- DT-AF-4
This detail shows connections of intersecting single 2x top plates with steel plates and alternate lumber splice connections.
Typical Details
- DT-AF-5
This detail shows an advanced framed wall junction with single top plates and 2x ladder blocking spaced vertically at 24” O.C. for an interior wall to exterior wall connection.
Typical Details
- DT-FR-5
This detail shows three-dimensional floor assembly of APA wood structural panel subflooring with gypsum concrete topping over joists and Type X gypsum wallboard ceiling below.
Typical Details
- DT-FR-6
Fire-rated load bearing interior chase wall assembly with gypsum wallboard, plywood sheathing, insulation cavity, and 1-inch space between stud walls at 16- or 24-inch centers.
Typical Details
- DT-AF-7
Typical Details
- DT-WB-2
This detail shows the alternate braced wall bracing method and its requirements including sheathing fastening, framing requirements, and foundation anchorage.
Typical Details
- DT-WB-4
This detail shows the wall bracing method continuously sheathed portal frame and its requirements including anchorage, minimum member sizes, and sheathing attachment.
Typical Details
- DT-WB-7
This detail shows the wall bracing method portal frame at a garage and its requirements including sheathing attachment, minimum member sizes, and anchorage.
Typical Details
- DT-WB-9
This detail shows the wall bracing method portal frame with hold down and its requirements including minimum framing sizes, sheathing attachment, hold-downs, and anchorage.
Technical Note
- D481
Provides design and construction practices that reduce the potential for buckling of wood structural panel sheathing caused by wood expansion due to increased moisture conditions.