Technical Document Library
Research-Backed Guidance for Every Project
Research-Backed Guidance for Every Project
Typical Details - DT-FR-1
This detail shows floor assembly of APA wood structural panel subfloor over plywood underlayment, building paper, and joists with gypsum wallboard ceiling below.
Technical Guides -
Market Analysis Reports - MKO-E191
Annual analysis of U.S., Canadian, and global economic factors impacting engineered wood demand, with multi-segment forecasts and historical production data. Available as PDF.
Case Studies - S115
This case study explains how glulam beams and engineered wood products shaped 2125 Franklin, a 735-bedroom mixed-use student housing building near the University of Oregon.
Data File - B840
This publication provides minimum requirements that plywood panels must meet to qualify for classification as APA 303 Series specialty siding.
Technical Guides - C800
Describes common engineered wood products: plywood, oriented strand board (OSB), I-joist, glued laminated timber (glulam), structural composite lumber (SCL) and rim board.
Technical Guides -
A Guide to the 2015 IRC Wood Wall Bracing Provisions
Technical Guides -
A Guide to the 2018 IRC Wood Wall Bracing Provisions + Free Digital 2021 Supplement
Technical Topic - TT-100
This publication describes the use of portal-frame design in engineered applications and as bracing in conventional light-frame construction
Technical Note - T230
This publication describes single- and double-layer all-wood floor assemblies for acoustic performance and includes both construction details and acoustic ratings
Construction Guide - M400
This publication explains the components of advanced framing in floor and wall framing, including illustrated construction details
Case Studies - T110
This case study explains how a Pennsylvania home builder gained a competitive advantage by adopting advanced framing techniques that deliver lasting energy savings to customers.
Technical Topic - TT-107
This publication answers questions regarding the performance of wood structural panels as air barriers
Case Studies - N110
This case study discusses how two mid-rise projects used all-wood podiums instead of concrete to cut construction costs, reduce building mass and improve sustainability.
Typical Details - DT-AF-1
This detail shows an alternative insulated 3-stud corner framing assembly with drywall clips to support the gypsum from one stud.
Standards - ANSI/APA PRP 210-2024
This ANSI/APA standard provides requirements and test methods for qualification and quality assurance for performance-rated engineered wood siding.
Technical Guides - X400
This publication explains the APA panel trademark and quality standards for wood structural panels
Typical Details - DT-EWG-1
This detail shows an APA glued floor system using APA Rated Sturd-I-Floor or sheathing panels.
Technical Guides - B707
Learn the APA research facility capabilities, including assembly-level testing of roof and floor building components and performance evaluation of lateral force resisting systems
Typical Details - DT-EWG-2
This detail shows APA Rated sheathing panels installed as roof decking over rafters or trusses with panel clips, asphalt or wood shingles, and proper edge and joint spacing.
Typical Details - DT-EWG-3
This detail shows APA panel stair treads and risers installed on stringers in two configurations, using plywood, OSB, or composite panels with 8d common nail fastening.
Typical Details - DT-EWG-4
APA Rated sheathing panels installed as subflooring over 2x joists, I-joists, or floor trusses with tongue-and-groove or blocked edges on a wood-framed floor system.
Typical Details - DT-EWG-5
This detail shows APA Rated wall sheathing applied in two orientations- strength axis across or parallel to studs- with weather-resistive barrier and siding on a wood-framed wall.
Technical Guides - V691
Discusses specifications and design details for the APA panel-deck block pallet, including load capacity, nailing schedules and materials handling system compatibility.
Technical Note - R280
This publication provides specification and installation recommendations for panel subfloors to be used under hardwood flooring
Technical Guides - W345 CA
This publication describes connection requirements and application notes for APA Performance Rated Rim Board for Canadian Limit States Design
Technical Topic - TT-060
Provides a recommendation for foam plastic roof insulation over minimum Performance Category 15/32 engineered wood panels that meet the 15-minute thermal barrier requirement
Typical Details - DT-EWG-6
This detail shows APA Rated lap siding installed over wood structural panel sheathing with a weather-resistive barrier on a wood-framed exterior wall assembly.
Typical Details - DT-EWG-7
This detail shows APA Rated siding panels applied over wood structural panel sheathing with a weather-resistive barrier on a wood-framed wall assembly.
Specification Guide - SP-1103
This publication provides an overview of the APA trademark and includes a sample specification for APA Rated Sheathing.
Typical Details - DT-FR-2
This detail shows a fire-rated wall assembly using wood structural panel sheathing over studs with gypsum wallboard, fire protective membrane, and glass fiber insulation.
Typical Details - DT-FR-3
This detail shows fire-rated exterior wall assembly with APA rated siding over sheathing, insulation, 2x4 wood framing at 16" on center and Type X gypsum wallboard interior finish.
Typical Details - DT-FR-4
This detail shows a one-hour fire-rated wood-framed wall assembly with Type X gypsum sheathing and wallboard, optional insulation, and APA rated siding exterior finish.
Technical Note - C465
This publication provides installation recommendations and test results for energy-saving APA Sturd-I-Wall construction
Specification Guide - SP-1102
This publication provides an overview of the APA trademark and includes a sample specification for APA Rated Sturd-I-Floor (OSB).
Specification Guide - SP-1102
This publication provides an overview of the APA trademark and includes a sample specification for APA Rated Sturd-I-Floor (Plywood).
Typical Details - DT-EWG-8
This detail shows APA Rated Sturd-I-Floor panel installation at 16", 20", or 24" o.c. joist spacing with tongue-and-groove edges over a floor framing system.
Typical Details - DT-EWG-9
This detail shows APA Rated Sturd-I-Floor panel installation at 32" or 48" o.c. joist spacing with tongue-and-groove joints over a crawl space floor framing system.
Typical Details - DT-EWG-10
This detail shows APA Rated Sturd-I-Floor 48 o.c. panels installed over a post-and-beam floor framing system with 4x4 posts, 4x girders, and tongue-and-groove panel edges.
Typical Details - DT-EWG-12
This detail shows APA Rated horizontal panel siding applied directly to wall framing in an APA Sturd-I-Wall system.
Typical Details - DT-EWG-13
This detail shows APA Rated vertical panel siding applied directly to wall framing in an APA Sturd-I-Wall system with weather-resistive barrier.
System Report - SR-101
This report discusses using wood structural panels to resist uplift from wind, including resistance to lateral shear forces and wind pressure perpendicular to the wall
System Report - SR-102
This report provides an approach to meet the requirements of the 2024, 2021, 2018, 2015 and 2012 IRC simplified wall bracing (Section R602.12).
System Report - SR-103
This publication outlines a construction solution to meet the IRC’s lateral and wind uplift load requirements using wood structural panels with raised-heel, or energy-heel, trusses
Technical Guides - Q230
This guide provides basic instructions for using the APA Wall Bracing Calculator
Technical Topic - TT-007
This publication recommends three methods for the installation of a wood floor system over a concrete slab: sleepers, rigid foam or direct.
Technical Topic - TT-126
Publication answers common questions about fire-protective coatings. Certification and inspection of products with fire-protective coatings are generally outside the scope of APA.
Case Studies - Q125
This case study explains how glulam beams were used to replace the flooring system of the historic Audrian Building, enabling the building to support multi-ton vintage automobiles.
Case Studies - V130
This publication describes how LEVER Architecture used engineered wood to balance design, budget and sustainability goals in a Portland, OR, commercial building project.
Typical Details - DT-SIP-1
This detail shows a SIP wall beveled to support a sloped SIP roof that are connected together with panel screws and nails. It also shows sealant, roofing material and cladding.
Typical Details - DT-BB-2
This detail shows chimney counter flashing detail of base flashing over shingle underlayment and roof deck, with counter flashing embedded in brick mortar joint.
Typical Details - DT-EWG-14
This detail shows brick veneer or masonry cladding installed over APA Rated wood structural panel sheathing.
Technical Note - F410
This publication describes mechanism and construction features that contribute to siding buckling
Build A Better Home - A520
This publication details common sources of moisture, preventive measures and design details for multiple foundation types, including slab-on-grade, crawl space and full basement.
Technical Guides - J440
This publication provides five basic steps to construct energy-saving wood wall systems that meet code, are durable to the forces of nature and help homeowners save money.
Builder Tip - S300
This publication describes how to reduce nail pops through recommended fastener selection and installation
Builder Tip - F435
This publication highlights essential details for using the APA narrow wall bracing method around garage openings.
Builder Tip - Q300
This publication describes how to prevent floor complaints and callbacks with proper floor sheathing installation
Builder Tip - K310
Describes installation techniques for plywood and OSB roof sheathing and roof ventilation techniques that will help minimize the potential for buckling of asphalt shingles
Builder Tip - M300
This publication contains spacing recommendations for APA Rated Sheathing, APA Rated Sturd-I-Floor® and APA Rated Siding.
Builder Tip - R340
This publication provides an overview of selection, handling, installation and fastening of APA plywood underlayment.
Technical Guides - M310
This publication illustrates nine construction details that improve wind resilience in residential construction, with real-world examples of each design
Technical Topic - TT-025
This publication discusses fire test results comparing the burn-through resistance of oriented strand board (OSB) and plywood.
Technical Topic - TT-091
Details the layups for APA 303 grooved plywood sidings (T1-11 and reverse board & batten), representing minimal plywood siding constructions as typically found in the marketplace.
Technical Guides - Q701
This publication is designed for use by mills as an aid in manufacturing and grading Canadian Standards Association (CSA) plywood panels.
Technical Note - X227
This publication discusses recommended maximum caster loadings for various wheel types and sizes on bare plywood, Plyron and overlaid plywood surfaces.
Technical Topic - TT-006
This publication describes Tile Council of North America (TCNA) specifications for wood structural panel floor systems under ceramic tile, tested in accordance with ASTM C627
Typical Details - DT-EWG-15
This detail shows a closed soffit assembly using APA rated roof sheathing and exterior panels for the closed soffit with continuous screened or louvered venting.
Technical Guides - V345
This publication contains grade information, form maintenance recommendations, design information and case studies related to plywood concrete forming
Technical Note - X485
This publication explains causes of condensation, identifies areas prone to condensation issues, and provides options to control condensation
Builder Tip - M300 LA
Recomendaciones de espacio entre paneles de clasificación “APA Rated Sheathing,” los pisos de clase Sturd-I-Floor® de APA y los paneles de clasificación “APA Rated Siding."
Builder Tip - S300 LA
Esta publicación describe cómo reducir los clavos sobresalientes con la selección e instalación recomendada de elementos de fijación.
Data File - D720
This publication identifies the causes of and remedies for excessive floor vibration.
Builder Tip - Q300 LA
Esta publicación describe cómo prevenir quejas y arreglos del sistema de piso con una instalación correcta del tablero estructural.
Technical Guides - X235
This publication discusses designing, building and specifying wood structural panel containers and bins for industrial materials handling applications.
Technical Note - R495
This publication discusses decay fungi and how to prevent/minimize degradation of wood through proper design, storage, construction and maintenance
Data File - L335
This publication provides recommendations for the installation and preparation of underlayment under finish flooring in residential and light commercial applications
Customer Service Tip - W505
This publication discusses the causes of fungal decay in wood structural panels and how proper design, construction and maintenance can prevent fungal decay.
Technical Topic - TT-123
This publication clarifies the applicability of the D+L deflection limits specified in Table 1604.3 of the 2018 IBC, specifically as they pertain to engineered wood products.
Technical Note - T555
This technical note presents a rational analysis for applying FTAO to walls with asymmetric piers and walls with multiple openings, based on APA modeling and testing
Technical Topic - TT-097
This publication explains the design considerations for installing a wood structural panel diaphragm over existing board sheathing (decking) in floors or roofs.
Technical Topic - TT-014
This publication describes various wood structural panel manufacturing processes that result in the eradication of insects
Technical Guides - L350
This publication provides design and construction recommendations for engineered diaphragm systems in floor, shear wall and roof systems
Technical Topic - TT-115
This technical topic presents the results and discussion of full-scale testing of double-sheathed shear walls with both layers of wood structural panels on a single side.
Technical Topic - TT-029
This publication discusses causes of surface dusting on concrete surfaces when poured against plywood forms and provides tips for prevention and remedial action.
Technical Topic - TT-075
This publication discusses a test program conducted by APA to investigate the effect of constructing shear walls with green framing lumber
Technical Topic - TT-012
This publication provides suggested guidelines for determining if overdriven fasteners will affect the shear capacity of diaphragm or shear wall construction
Typical Details - DT-EWG-16
This detail shows two energy-conserving exterior wall assemblies.
Typical Details - DT-RH-1
This detail shows raised heel energy truss attachment to an exterior wall for additional attic insulation space.
Technical Guides - E30
This publication provides a comprehensive overview of engineered wood construction systems for residential, commercial and industrial buildings
Excerpt - E30X-AFBS
Summary of special systems, including fire resistant construction, fire protected assemblies, wind-resistive roofs, energy conservation and panels over metal framing
Excerpt - E30X-FC
This publication is an excerpt from the APA Engineered Wood Construction Guide, providing information about floor framing and wood structural panel products
Excerpt - E30X-PSS
This publication is an excerpt from the APA Engineered Wood Construction Guide, providing product descriptions and specification recommendations for wood structural panels
Excerpt - E30X-RC
This publication is an excerpt from the APA Engineered Wood Construction Guide, providing a description and application recommendations for engineered wood roof materials
Excerpt - E30X-WC
This publication is an excerpt from the APA Engineered Wood Construction Guide, providing application recommendations for APA wood structural panel wall sheathing.
Construction Guide - R300
Provides specification recommendations for plywood and OSB floor systems, the APA Glued Floor System and installation recommendations for panel subflooring and underlayment
Case Studies - W170
This case study discusses two Washington school districts that creatively leveraged the benefits of exposed wood products in newly constructed schools.
Technical Guides - X505
This publication provides a list of engineered wood products and common construction terminology explained in easy-to-understand language.
Case Studies - Z110
This case study discusses how a Sprouts grocery store used engineered wood instead of steel for the roof system to solve supply chain challenges and reduce their carbon footprint.
Construction Guide - R310
This publication provides an overview of commonly used wall systems and explains how wood structural panels can be used to meet fundamental requirements in wall applications
Case Studies - X175
This publication discusses how a California nonprofit incorporated engineered wood into an affordable housing complex to keep costs low and create an inclusive community
ESR Joint Evaluation Report - ESR-1301
OSB:
Typical Details - DT-BB-3
This detail shows exterior deck ledger connection to wood I-joist floor system of water-resistant flashing.
Technical Topic - TT-133
This publication discusses buckling, fastener recommendations, surface flaking, thickness swell, linear expansion and moisture management of OSB wood structural panels
FAQ - F505
This publication answers questions about structural plywood and OSB panel performance, grade, growth and natural characteristics.
FAQ - X501
This publication provides guidance about the serviceability of wood structural panels (plywood and OSB) after exposure to high levels of moisture.
Technical Note - E830
This publication summarizes APA test data on ultimate withdrawal and ultimate lateral loads for plywood joints fastened with wood screws and sheet metal screws.
Technical Note - J805
This publication describes methods for field restoration of plywood to near its original condition and appearance
Builder Tip - Q350
This publication describes recommended finishes and application recommendations for APA Rated Siding.
Technical Guides - W305
This publication is a guide to cost-effective fire-rated wood and wood structural panel systems that meet code requirements
Technical Note - K320
Discusses fire-retardant-treated plywood specifications, code-compliant applications, testing standards and structural requirements for commercial and residential construction.
Technical Topic - TT-010
This publication summarizes surface burning characteristics (flame spread and smoke development) of wood structural panels tested in accordance with ASTM E84
Technical Topic - TT-128
This publication discusses the results of a series of CAN/ULC-S102 tests of flame-spread rating (FSR) and smoke developed classification (SDC) for OSB sheathing in Canada
Technical Note - C468
This publication discusses typical floor squeak causes and provides corrections and preventative measures.
Typical Details - DT-EWG-17
This detail shows an FM Class 1-105 rated flat roof assembly using wood structural panels over open-web trusses.
Typical Details - DT-EWG-18
This detail shows an FM Class 1-120 rated flat roof assembly using wood structural panels over steel joists.
Typical Details - DT-EWG-19
This detail shows an FM Class 1-135 rated flat roof assembly using wood structural panels.
Typical Details - DT-EWG-20
This detail shows an FM Class 1-90 rated flat roof assembly using wood structural panels with foam insulation, fiberboard cover board, and built-up or modified bitumen roofing.
Typical Details - DT-SIP-2
This detail shows roof SIPs sloped up to form a ridge and connections of the SIPs to framing members with panel screws, while also showing tape, sealant, and roofing materials.
Typical Details - DT-FTO-1
This detail shows the layout of a force transfer around opening shear wall.
Technical Note - J330
This publication addresses concerns related to formaldehyde in engineered wood products and explains their exemption from leading formaldehyde emission standards and regulations.
Technical Topic - TT-080
This publication answers FAQs about portal frame construction from the APA 2018 IRC wall bracing webinar series
Case Studies - X170
This case study discusses how the Las Ventanas affordable housing project used glulam, LVL, OSB and FTAO design principles to cut costs and streamline construction.
Typical Details - DT-SIP-3
This detail shows how to attach a floor system in between the top and bottom of two SIP walls by hanging the joists at the top of a SIP with top mount hangers and a cap plate.
Technical Topic - TT-024
This publication discusses how to avoid floor panel puncture from drywall carts by consulting PS 2 for minimum concentrated static loads and heavy concentrated loads
Typical Details - DT-EWG-21
This detail shows a heavy timber roof construction assembly using APA Rated Sturd-I-Floor T&G panels over structural glulam or solid timber beams with built-up roofing.
Typical Details - DT-EWG-22
This detail shows three horizontal beltline joint configurations for APA panel siding at floor lines in multistory construction.
Typical Details - DT-EWG-23
This detail shows three horizontal joint configurations for APA panel siding — butt and flash, lap, and shiplap — each with blocking flatwise or edgewise at the joint location.
Technical Topic - TT-129
This publication presents four construction details for incorporating 2-inch-thick foundation foam insulation into residential I-joist floor assemblies.
Technical Guides - P320
Joint ICC and APA publication describes how energy performance is measured in exterior wall assemblies and how to improve wall thermal performance to meet energy code requirements
Product Advisory - SP-1185
This publication provides test results for imported plywood panels from Brazil, evaluated for conformance to U.S. Product Standard PS 1
Typical Details - DT-EWG-24
This detail shows APA plywood underlayment installation over APA Rated sheathing subfloor.
Data File - Q370
This publication describes recommended wall construction methods for the installation of stucco exterior finish over structural wood panel wall sheathing
Typical Details - DT-AF-2
This detail shows an insulated three-stud outside corner (California corner) framing assembly.
Typical Details - DT-AF-3
This detail shows an insulated three-stud inside corner framing assembly.
Technical Guides - X305
This publication explains how to design wood-frame buildings to withstand the lateral loads typical of high wind and seismic zones.
Technical Guides - F430
This publication explains IRC-compliant wall bracing, explains why bracing is important and shows how to meet basic requirements for wall bracing in accordance with the code
Research Report - M410
This report contains research results on force transfer around openings (FTAO). This study was a joint effort between APA, the USDA FPL and the UBC.
Technical Guides - A236 LA
las especificaciones de la norma PS 1 para madera contrachapada para cumplir con los criterios de rendimiento de los materiales establecidos en ACI 318/347, según lo exige el IBC
Product Advisory - SP-1172
This product advisory contains results of testing to measure the shear wall performance of Thermo-Ply® sheathing
Data File - Z350
This publication describes techniques and products for code-required connections in wood roof systems in high wind and seismic zones.
Typical Details - DT-FR-5
This detail shows three-dimensional floor assembly of APA wood structural panel subflooring with gypsum concrete topping over joists and Type X gypsum wallboard ceiling below.
Technical Topic - TT-063
This publication discusses the advantages of using IBC and UL recognized oriented strand board (OSB) and plywood wall assemblies over other products.
Typical Details - DT-FR-6
Fire-rated load bearing interior chase wall assembly with gypsum wallboard, plywood sheathing, insulation cavity, and 1-inch space between stud walls at 16- or 24-inch centers.
Technical Note - Q225
This publication contains uniform load tables for APA trademarked wood structural panels that are manufactured and qualified in accordance with PS 1, PS 2 and APA PRP-108
Technical Guides - M200
This publication discusses the use of APA-trademarked wood structural panels in materials handling applications including pallets, crates, bins, shelving and mezzanine floors.
Typical Details - DT-WB-2
This detail shows the alternate braced wall bracing method and its requirements including sheathing fastening, framing requirements, and foundation anchorage.
Typical Details - DT-WB-4
This detail shows the wall bracing method continuously sheathed portal frame and its requirements including anchorage, minimum member sizes, and sheathing attachment.
Typical Details - DT-WB-7
This detail shows the wall bracing method portal frame at a garage and its requirements including sheathing attachment, minimum member sizes, and anchorage.
Typical Details - DT-WB-9
This detail shows the wall bracing method portal frame with hold down and its requirements including minimum framing sizes, sheathing attachment, hold-downs, and anchorage.
Technical Note - D481
Provides design and construction practices that reduce the potential for buckling of wood structural panel sheathing caused by wood expansion due to increased moisture conditions.
Typical Details - DT-FR-7
Fire-rated wall assembly of two UL-rated configurations (U330 and U335) with different exterior finishes over wood framing with mineral wool or glass fiber insulation.
Typical Details - DT-FR-8
This detail shows fire-rated wall assembly detail of 3/8" APA rated plywood siding over Type X gypsum wallboard with optional insulation on 2x4 studs at 16" on center.
Technical Note - R525
This publication provides recommendations for minimizing moisture accumulation in panelized low-slope roof systems in commercial and industrial applications
Technical Topic - TT-002
This publication provides recommended bond classification appropriate for end use in-service moisture conditions.
Technical Topic - TT-028
This publication discusses linear expansion and thickness swell in wood structural panels due to moisture
Market Analysis Reports - MHRS-26
Monthly U.S. & Canadian housing market analysis covering starts, permits, home sales, mortgage rates, remodeling, and wood product demand indicators. Annual subscription.
Technical Topic - TT-098
This publication discusses the benefits of mulching construction-related wood scraps, including glued engineered wood products
Technical Guides - Q250
Determine the type and spacing of siding fasteners to meet building code requirements when using wood structural panel sheathing as a nail base (also called nailable sheathing)
Typical Details - DT-WOM-1
This detail shows wood nailer attachment to steel wide flange beam using drive pins to support APA panel deck, secured with power driven fasteners.
Technical Guides - W460
This publication is a guide to noise-rated wood-frame construction systems, including STC and IIC ratings for tested wall and floor assemblies for effective sound control.
Typical Details - DT-EWG-26
This detail shows noise-resistant floor/ceiling assembly using APA Rated sheathing subfloor, lightweight concrete topping, resilient channels, and gypsum wallboard.
Typical Details - DT-EWG-27
This detail shows a noise-resistant wall assembly in plan view using staggered 2x4 studs on 2x6 plates with APA Rated sheathing and gypsum wallboard to reduce sound transmission.
Technical Note - B429
This publication explains how to determine partition load, including situations where additional joists are required to account for the weight of partition walls.
Typical Details - DT-EWG-28
This detail shows one-hour fire-resistive floor/ceiling assemblies using wood I-joists with APA Sturd-I-Floor decking and gypsum wallboard ceiling systems with furring channels.
Typical Details - DT-EWG-29
This detail shows two one-hour fire-rated floor/ceiling assemblies with lumber joists.
Typical Details - DT-EWG-30
One-hour fire-rated exterior wall assembly using APA Rated siding, gypsum sheathing, weather-resistive barrier, and Type X gypsum wallboard over 2x4 wood stud framing.
Typical Details - DT-AF-8
This detail shows a one-sided box header built using wood structural panels on the exterior face of the wall to eliminate conventional headers and increase cavity insulation space.
Typical Details - DT-EWG-31
This detail shows APA Rated sheathing panels installed as an open soffit on exposed roof rafters with weather-protected edges.
Product Guide - W410
This product guide provides an overview of oriented strand board (OSB) and discusses OSB composition, properties, code acceptances and applications
Technical Guides - D510
This publication describes recommended design capacities (ASD) and design methods for wood structural panels manufactured under PS 1 and PS 2 and APA Performance Standard PRP-108.
Technical Note - R275
This publication provides recommendations from APA research on the performance of 24-inch and narrower roof sheathing panels
Technical Topic - TT-054
This publication provides guidance on how to comply with NIST panel thickness regulations while still providing for traditional specifications used in the U.S. model building codes
Typical Details - DT-WOM-2
This cross-section detail shows APA panel deck attachment to metal C or box section joist using hardened screwshank nails or self-tapping fasteners with optional adhesive.
Builder Tip - N330
This publication discusses recommended panels and spans for open and closed soffits.
Typical Details - DT-WOM-3
This connection detail shows APA panel deck attachment to nailable steel joists using hardened screwshank nails and 2x4 nailer blocking at panel edges.
Product Advisory - SP-1186
This publication discusses overstated published lateral load design properties of eight flexible structural sheathing products
Product Guide - F405
This product guide describes performance standards, applications, trademark and performance category information for APA Performance Rated Panels
Standards - E445
This publication describes requirements and test methods for APA Performance Rated Panels (APA Rated Sturd-I-Floor®, APA Rated Sheathing and APA Rated Siding).
Technical Guides - Y510
This publication includes section properties, recommended design stresses and design methods for plywood manufactured under Voluntary Product Standard PS 1
Technical Guides - S811
This publication presents the recommended method for the design and fabrication of curved plywood roof panels. It is a supplement to the APA plywood design specification.
Technical Guides - S812
This publication presents the recommended method for the design and fabrication of glued plywood and lumber beams.
Technical Guides - U813
This publication provides recommendations for the design and fabrication of plywood stressed-skin panels. It is a supplement to the APA Plywood Design Specification.
Technical Guides - U814
This publication presents the recommended method for the design and fabrication of flat plywood sandwich panels. It is a supplement to the APA Plywood Design Specification.
Technical Guides - H815
This publication presents the recommended methods for the design and fabrication of staple-glued all-plywood beams.
Technical Topic - TT-047
This publication discusses the standards under which plywood and oriented strand board (OSB) are qualified and the interchangeability of the two products, depending on the end use
APA Product Reports - PR-C302
Plywood:
APA Product Reports - PR-E710
Hardel Mutual Plywood Corporation, Rayonier, Roseburg Forest Products Company, Tolko Industries Ltd.
APA Product Reports - PR-N117
OSB:
APA Product Reports - PR-N124
OSB:
APA Product Reports - PR-N127
OSB:
APA Product Reports - PR-N129
OSB:
APA Product Reports - PR-N133
OSB:
APA Product Reports - PR-N137
OSB:
APA Product Reports - PR-N138
OSB:
APA Product Reports - PR-N139
OSB:
APA Product Reports - PR-N140
OSB:
APA Product Reports - PR-N141
OSB:
APA Product Reports - PR-N213
OSB:
APA Product Reports - PR-N215
OSB:
APA Product Reports - PR-N216
OSB:
APA Product Reports - PR-N414
OSB:
APA Product Reports - PR-N610
LP, Tolko Industries Ltd., West Fraser Timber Co. Ltd.
APA Product Reports - PR-N612
OSB:
APA Product Reports - PR-N614
OSB:
APA Product Reports - PR-N801
OSB:
APA Product Reports - PR-V180
Plywood:
Typical Details - DT-EWG-32
This detail shows a prefabricated APA wood structural panel roof assembly with purlins installed perpendicular to the supports.
Data File - Q220
This publication discusses preservative-treated plywood covering treatment types, use categories, retention levels, fasteners, finishing and safe handling per AWPA standards.
Technical Note - T350
This publication discusses how to minimize the risk of future wood flooring problems when moisture at the jobsite is an issue
Product Guide - B360
Describes high density overlay (HDO) and medium density overlay (MDO) plywood applications, properties and characteristics, and shop practice and finishing recommendations
Product Guide - E300
Describes the following for performance rated siding: face grades, textures and patterns; finishing; ordering/specifying; basic application recommendations
Product Guide - K435
This publication describes the specification, advantages, applications and finishing recommendations of sanded plywood and includes trademark examples and explanations
Builder Tip - N335
This publication provides step-by-step instructions for roof sheathing installation
Market Analysis Reports - QPRO-26
The APA Quarterly Production Report delivers comprehensive, up-to-date data on North American structural wood panel and engineered wood product markets
Market Analysis Reports - QPRO-26
The APA Quarterly Production Report delivers comprehensive, up-to-date data on North American structural wood panel and engineered wood product markets
Typical Details - DT-CWA-1
This detail shows R20 2x4 wall assembly at 16" o.c. with insulated header, insulated siding (R3 min.), insulated corner, R15 cavity insulation, and wood structural panel sheathing.
Typical Details - DT-CWA-2
R20 advanced framing wall assembly at 24" o.c. minimum with insulated corner, engineered wood or lumber header, R19 compressed fiberglass batts & wood structural panel sheathing.
Typical Details - DT-CWA-3
This detail shows R20 wall assembly at 24" o.c. with insulated header (R13.8), insulated corner, R21 cavity insulation, and wood structural panel sheathing with wood/vinyl siding.
Typical Details - DT-CWA-4
This detail shows R20 wall assembly with insulated siding (R2 min.), engineered wood or lumber header, wood structural panel sheathing, and R19 compressed fiberglass batts.
Typical Details - DT-CWA-5
This detail shows R21 advanced framing wall assembly with insulated header and corner, wood structural panel sheathing, and fiberglass batt insulation at 16" or 24" o.c. spacing.
Typical Details - DT-BB-4
This detail shows rain-screen wall assembly of furring strips creating a drainage airspace over water-resistive barrier and wood structural panel sheathing.
Technical Guides - R330
This publication describes the key components of raised-heel trusses and identifies the advantages of using them in conjunction with continuous wood structural panel wall sheathing
Technical Topic - TT-119
This publication describes APA recommended guidelines for snow and ice accumulation on wood structural panels
Technical Topic - TT-021
Table of recommended uniform live loads for PS 1 APA 303 siding when used as open soffit or combined roof decking-ceiling with long dimension perpendicular to supports.
Technical Topic - TT-105
This publication discusses the International Residential Code (IRC) wall sheathing requirements regarding wind pressure
Research Report - E315
This publication describes tests of high-load diaphragms with multiple rows of fasteners, glued diaphragms, and diaphragms with openings
Research Report - Q260
This report includes test results of unblocked, stapled and metal-framed shear walls, and a summary of previous shear wall tests.
Customer Service Tip - W503
This publication discusses the causes, prevention and remedial treatment for floor sheathing ridging.
Typical Details - DT-SIP-4
This detail shows installation of a floor system between the top and bottom of two SIP walls with the joists directly on top of the SIP with a cap plate and rim board end closure.
Construction Guide - R305
This publication provides specification recommendations for plywood and OSB roof systems and installation recommendations for panel roofs
Typical Details - DT-BB-5
This detail shows pan and cover tile roof ridge detail of APA rated sheathing.
Case Studies - S125
This case study discusses how glulam beams and wood structural panel shear walls were used to construct a California apartment complex on budget.
Technical Topic - TT-052
This publication provides information about the performance, proper specification and application of oriented strand board (OSB) products.
Data File - Y250
This publication discusses diaphragm perimeter nailing and transfer of shear wall forces from the walls above into the foundation/wall framing.
Typical Details - DT-EWG-33
This detail shows a hold down anchor assembly connecting a shear wall to a concrete foundation to resist overturning forces.
Technical Topic - TT-076
This publication provides an evaluation of double 2x framing members as substitutes when single 3x framing members at adjoining panel edges are specified by code for shear walls
Technical Topic - TT-087
This publication provides results from full-scale shear-wall tests and demonstrates the conservative capacities given in ESR-1539.
Technical Guides - T210
This publication details 10 common sources of air infiltration that should be checked and sealed during construction
Typical Details - DT-FR-16
This detail shows a single-layer 23/32" T&G APA Sturd-I-Floor assembly over wood I-joists with hat-shaped furring channels, mineral fiber batts, and Type C gypsum wallboard ceiling
Typical Details - DT-FR-20
Single-layer tongue and groove APA-rated sheathing over wood I-joists with resilient channels and two layers of gypsum wallboard ceiling assembly for residential construction.
Typical Details - DT-FR-15
Single-layer tongue and groove APA-rated sheathing over wood I-joists with resilient channels and two layers of gypsum wallboard ceiling assembly for residential construction.
Typical Details - DT-FR-18
Single-layer tongue and groove APA-rated sheathing floor system with wood I-joists, hat-shaped furring channels, gypsum wallboard ceiling, and mineral fiber insulation.
Typical Details - DT-FR-19
This detail shows a single-layer floor assembly using 23/32 T&G APA Sturd-I-floor over wood I-joists with resilient channels, insulation, and gypsum wallboard ceiling finish.
Typical Details - DT-FR-21
This detail shows single-layer wood I-joist floor system with 23/32" T&G APA rated sheathing and two layers of 1/2" gypsum wallboard ceiling providing a fire-rated assembly.
Typical Details - DT-SIP-5
This detail shows a wall-to-wall vertical SIP connection using a block spline and specifies nail size, nail spacing, use of sealant, and an 1/8” expansion gap.
Typical Details - DT-SIP-6
This detail shows a wall-to-wall vertical SIP connection using a dimensional lumber spline and specifies nail size, nail spacing, use of sealant, and an 1/8” expansion gap.
Typical Details - DT-SIP-7
This detail outlines the construction of an eave using a SIP, highlighting proper flashing, sealant, and roofing materials.
Typical Details - DT-SIP-8
This detail shows a SIP wall assembly being attached to a floor system bearing on a concrete/CMU foundation wall, highlighting proper assembly of wall, floor, and foundation.
Technical Topic - TT-055
This publication discusses the SIZED FOR SPACING notation in the APA trademark stamp and the option of trimming panels slightly to encourage proper panel spacing
Typical Details - DT-BB-7
This detail shows slab-on-grade foundation detail of moisture control layers.
Technical Topic - TT-058
This publication discusses the practice of driving nails at a slight angle in shear walls and diaphragms, and the difference between slant nailing and toe-nailing.
Customer Service Tip - W501
This publication explains why wood structural panels sometimes feel soft or springy.
Technical Topic - TT-059
This publication discusses the causes of concrete staining and provides some possible solutions
Builder Tip - U450
This publication provides guidelines to help protect panels from damage in storage, during shipment and on the jobsite
Typical Details - DT-FTO-2
This detail shows the blocking requirement for the metal strap at the exterior or interior of a force transfer around the opening shear wall.
Product Guide - H650
This publication covers SIP advantages, applications, design and construction considerations, connection details, assembly and related topics.
Typical Details - DT-FR-22
This detail shows a fire-rated wall assembly of stucco over self-furring metal lath with APA rated sheathing, optional insulation, gypsum wallboard, and wood studs.
Typical Details - DT-EWG-34
Stucco cladding assembly applied over APA Rated wood structural panel sheathing with two layers of weather-resistive barrier, self-furring metal lath, and metal bead.
Technical Guides - V440
This publication provides guidelines on installing wood structural panel subfloors for optimal performance of finished floors.
Technical Guides - F305
Describes the environmental benefits of engineered wood, compares wood to other structural products and explains scientific research that demonstrates woods green building merits.
Technical Guides - R311CAF
Aperçu des systèmes de murs couramment utilisés et de la manière dont les panneaux structuraux en bois peuvent satisfaire aux exigences fondamentales dans les applications murales.
Technical Note - J735
Provides recommendations for properly placing heavy loads in a partially completed light-framed structure to prevent damage to the structure and/or injury to the work crew
Technical Note - U425
This publication discusses expansion joint details for buildings with dimensions larger than 80 feet
Technical Note - K830
This publication discusses the types of termites found in the U.S. and proven construction techniques and treatment methods to protect wood-frames buildings from termite damage.
Damage Assessment Report - SP-1182
This report summarizes the findings of a team of engineers who visited the site of a 2017 Texas windstorm to assess the damages sustained by residences
Damage Assessment Report - SP-1177
This publication contains damage assessments from the December 2015 tornado storm near Dallas, TX, including wind-resistant construction recommendations
Technical Guides - A236
This publication describes the importance of adhering to PS 1 plywood specifications to meet the material performance criteria outlined in ACI 318 & ACI 347, as mandated by the IBC
Technical Guides - R505
This publication explains how to use a performance path to meet International Energy Conservation Code (IECC) requirements while balancing cost and structural requirements.
Typical Details - DT-FR-23
This detail shows two-hour fire-rated load-bearing interior or exterior wall assembly with 2x6 wood studs, mineral wool insulation, and Type X gypsum wallboard on both sides.
Typical Details - DT-AF-9
This detail shows a two-sided box header built using wood structural panels on both sides of the wall in lieu of conventional headers to increase cavity insulation space.
Typical Details - DT-AF-14
This detail shows a plan view of a two-stud corner framing assembly with 2x ladder blocking spaced vertically at 24 inches on center to provide interior drywall backing.
Typical Details - DT-AF-15
This detail shows a two-stud outside corner framing assembly using drywall clips to secure interior drywall without requiring a third corner stud.
Typical Details - DT-AF-16
This detail shows a two-stud inside corner framing assembly with a panelized/prefabricated wall system.
Typical Details - DT-EWG-35
This detail shows four connection methods for flat roof systems: to wood I-joists, open-web parallel-chord wood trusses, steel bar joists with wood nailer and glulam beams.
Typical Details - DT-EWG-36
This detail shows 4 methods for attaching APA panel deck to metal framing systems including nailable steel joists, nailer-anchored, and direct-to-formed steel joist configurations.
Typical Details - DT-WWR-1
This detail shows a UL Class 90 rated roof assembly using two-ply asphalt glass fiber mat over plywood deck with Douglas-fir or Southern pine framing.
Typical Details - DT-WWR-2
This detail shows a wind-resistive roof assembly with hot-mopped built-up roofing over APA-rated plywood sheathing and structural framing, rated U.L. Class 90.
Typical Details - DT-EWG-37
This detail shows vertical corner joint configurations for APA panel and lap siding — butt and caulk, corner board lap joints, and lap siding corners — in horizontal section view.
Typical Details - DT-EWG-38
This detail shows four vertical joint configurations for APA panel siding butt, shiplap, reverse board and batten, T1-11 and channel groove, and vertical batten.
Standards - L870
This publication is the national standard for performance requirements and marking plywood for construction and industrial uses.
Standards - S350
Performance requirements, adhesive bond performance, panel construction and workmanship, dimensions and tolerances, marking and moisture content of wood structural panels.
Typical Details - DT-BB-8
This detail shows two-piece flashing installation at wall penetration.